Pioneer CDX-MG6036ZH Service Manual page 51

6 disc in-dash cd changer
Table of Contents

Advertisement

- CD Changer Mechanism Flowchart
[Key]
[EJECT]+Reset
Test Mode In
Contents
Display
[CD]or[SOURCE]
Source CD
DSC
??
[ASEL]
Mechanism Test In
Initial State
DSC
[RPT]
Mecha Test Out
CAM MOTOR
CD Test In
DSC
TRK
DSC
6
6
00
- Operating Procedures:
1)
Turn on the CD Test Mode, then select the
CD-MULTI for the SOURCE.
2)
Select the motor to be driven
using the [1] to [4] keys.
3)
Press the [FF] or [REV] in this state to drive
the selected motor.
<Screen Display during Mecha Test Mode>
TRK 72
TRK : 72
72 : Mecha Test Mode
is turned on
MIN : Upper (10th order):
Type of motors selected
1* : CAM motor
2* : ELV motor
3* : LOAD motor
4* : CAM+LOAD motor
An example when TRK 72, MIN 10 and SEC 31:
Test Mode is turned on from TRK 72.
CAMMOTOR is selected from 1 of MIN 10 and PH1/PH2
are selected from 0. All MAX switches are set to L (low).
As for SEC 31, since CAMMOTOR is selected from MIN,
CAM gear CLAMP switch is set to L (low) and others are
H (high) from SEC1.
TRK
55
TRK
6
72
[1]
[2]
ELV MOTOR
LOAD MOTOR
select
select
TRK
TRK
DSC
DSC
1*
6
2*
TRK
(
)
?*
MIN
Lower (order of 1): State of DISC
sensing phototransistor and switch
PH1 PH2 MAXSW Display
L
L
L
*0
H
L
L
*1
L
H
L
*2
H
H
L
*3
L
L
H
*4
H
L
H
*5
L
H
H
*6
H
H
H
*7
L:
Phototransistor is OPEN and switch is ON.
H:
Phototransistor is CLOSE and switch is OFF.
[RPT]
CD Test Mode
TRK
DSC
6
00
[3]
[4]
CAM+LOAD MOTOR
MOTOR FWD drive
select
select
TRK
TRK
DSC
6
3*
6
4*
[Key]
[ASEL]
Mechanism Test is initialized.
Valid only when the motor selected (using the
[FF]
[1] to [4] keys) is driven in FWD direction.
Valid only when the motor selected (using the
[REV]
[1] to [4] keys) is driven in REV direction.
[1]
CAM MOTOR is selected.
[2]
ELV MOTOR is selected.
[3]
LOAD MOTOR is selected.
[4]
CAM + LOAD MOTOR is selected.
**
SEC
SEC : 1 When ELV motor is selected, ELV position is displayed
01: ELV at home position (1st disc).
10: ELV at a position other than home (2nd to 6th).
11: ELV moving to a specified position. * Note 1
00: Reserved (for an error)
2 When CAM.LOAD motor is selected:
Indicates CAMSW (CAM gear) status.
Display
10
REV
EJECT
SW1 (DOORSW)
SW2 (LOADSW)
SW3 (MODESW)
SW4 (CLAMPSW)
- Precautions
*
The keys are inoperable as long as operation of the mechanism is continued.
When driving the CAMMOTOR in 31 → 30 → 10 (in REV direction),
*
the elevation position must be at the EJECT/LOAD position (the top position).
Note 1:
When the elevation is situated at the Note 1 position, move of any motor
other than the REV is disabled.
Note 2:
Before performing the elevation, make sure that the CAM SW (switch) is
set to a position between 22 and 20.
As a rule, driving of the ELV MOTOR must be started immediately after
the CAMSW indication has changed from 22 to 20.
CDX-MG6036ZH
[TR+]
CD Test Mode
DSC
TRK
6
99
[FF]
[REV]
MOTOR REV drive
DSC
TRK
TRK
DSC
6
**
6
**
Operation
##
30
31
21 20 22 23
33 32
Note 2
FWD
clamp
51

Advertisement

Table of Contents
loading

Table of Contents