Modules Present - Actron CP9680 User Manual

Auto scanner plus
Table of Contents

Advertisement

Charging System Monitor
DLC KOEO Voltage:
12.2V
Please start the engine
Press BACK to exit
4.
When the cranking condition is detected, the scan
tool will begin collecting DLC voltage readings.
If the engine starts, press
Charging System Monitor
Collecting data
Press ENTER when the engine
has started
5.
If an engine started condition is detected, the scan
tool will collect key on engine running DLC voltages.
Charging System Monitor
Determining DLC KOER voltage
Press BACK to exit
6.
The test results are then displayed.
Test Results
DLC KOEO Voltage
DLC Cranking Voltage
DLC KOER Voltage
ess ENTER to view the data plot.
Bosch Automotive Service Solutions Inc.
On the first screen, the Scan Tool didn't detect that the
engine had started, so there isn't a KOER voltage read-
.
ing.
The second screen did detect that the engine had
started so there is a KOER reading.
The screen on the left shows that the KOEO voltage
before an engine start was attempted was 12.2V. Once
the starter began cranking the engine, a cranking voltage
of 10.4V was measured. After the engine started, a KOER
voltage reading of 14.7V was measured.
If the KOEO voltage is very low, this could be an
indication of a bad battery, or one that needs to be
charged.
If the cranking voltage is a lot lower than the KOEO
voltage, than this is an indication of a worn starter.
If the KOER voltage is not higher than the KOEO
voltage, than this indicates a bad or weak alternator.
After reviewing the test results, Press
data plot.
7.
View the data plot.
12.2
10.4
---
8.
Press
5.17
The Scan Tool identifies the module IDs and communica-
tion type for all Global OBD II modules in the vehicle.
From the Special Tests Menu:
1.
Select Modules Present.
CP9680 AutoScanner® Plus | User guide | 41 | en
Test Results
DLC KOEO Voltage
DLC Cranking Voltage
DLC KOER Voltage
ess ENTER to view the data plot.
The triangle below the graph indicates the
position of the frame in the graph.
Use the
LEFT and
RIGHT arrow keys to
scroll back and forth through graph.
DLC Pin 16 Voltage
14.7
10.4
Frame:
0
Time:
to return to the Special Tests Menu.

Modules Present

Use the
UP and
DOWN keys until Modules
Present is highlighted.
Press
.
12.2
10.4
14.7
to view the
10.6
0.00
573102 | REV. A | 07.2015

Advertisement

Table of Contents
loading