10. Install charge pipe #1 onto turbo compressor outlet with supplied gaskets and M6 bolts.
Loosely fit silicone coupler onto charge pipe #1. See Fig. 16 & 17
11. Install silicone coupler onto intake manifold loosely. Insert charge pipe #2 into intake manifold
coupler and charge pipe #1 coupler. Once lined up, secure clamps. See Fig. 18 & 19 note: turbo
compressor housing can be loosened and rotated to ease with alignment of the piping.
12. Install reducing coupler onto turbo compressor inlet with supplied clamps. Install turbo inlet
pipe and overlay factory rubber hose from the air box over the inlet pipe and mark about 2.5" past
the charge pipe and cut rubber coupler to length. Insert charge pipe into coupler and secure with
clamps. See Fig 20, 21 & 22