Maintenance • Mantenimiento
Entretien • Manutenção
5
5
3
2
*
EWC 3 08 0 =

2
4
European waste disposal key
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
english
Prior to maintenance work:
• Shut off condensate inlet (if necessary
switch off compressor).
• If there is an in-built heating system,
disconnect the device from the power
supply!
Cleaning of dirt collector
(recommended every 6 months)
• Keep a basin at hand for catching the
dirt.
• Detach the inlet adapter from the pres-
sure relief chamber.
• Undo the screws.
• Slowly lift out the pressure relief
chamber.
• Pull out the plug, catch the dirt, and
ensure correct disposal
• Put back the plug, reinstall the pres-
sure relief chamber, reconnect the inlet
adapter.
Checking of oil outlet
(recommended every 6 months)
Remove the pressure relief chamber (as
described above).
• Check oil overflow edge for dirt, clean
if necessary.
Reinstall the pressure relief chamber.
General cleaning of ÖWAMAT
(recommended every 12 months)
Clean dirt collector.
1
Empty the preseparation tank *
2
Clean the preseparation tank.
6
3
Empty main tank *
Clean main tank.
Empty oil collector (see page 20)
4
Disposal of the liquid.
Note:
Do not add any cleaning agents (sur-
1
factants or flammable cleaners)! They
impair the filter efficiency.
After cleaning:
Insert new OEKOSORB filter set (see
5
page 22).
Insert new filter mat.
6
Fill ÖWAMAT unit with clean water
(see page 18).
After maintenance work
• Open condensate inlet.
• If there is an in-built heating system,
reconnect the power supply.