SERVICE TEST PROGRAM

KEY
TEST
N
VOLUME+
Button pressed?
Y
Display shows
"Key"
KEY
N
Any
NEXT
Button pressed?
PREV
The corresponding codes
according to Table 1 will be
displayed
STOP
N
STOP
Button pressed?
PLAY
Y
Main Set Key
DISPLAY
32
STANDBY-ON
OPEN*CLOSE
29
SOURCE-
11
DBB
17
BAND
10
PROGRAM
14
18
19
PLAY
20
VOLUME+
24
VOLUME-
23
PREVIOUS(
)
12
NEXT (
)
13
Table 1
3-1
To start service test program
PLAY & SOURCE
depressed while
plugging in the mains cord
Display shows the
VER refers to Version
ROM version
"VER XXX"
XXX refers to Software version number of the uProcessor
(Main menu)
(counting up from 010 to 999)
COMPACT DISC
TEST
Note : Disc should be available on the tray before entering the Service Test Mode.
MESSAGE
DISPLAY
ACTION
OKAY
ERROR
MOTOR 1
-
-
Disc motor turns clockwise, motor power 50%.
MOTOR 2
-
-
Disc motor turns counter clockwise, motor power 50%
SLE OUT
-
-
Slide moves outside.
SLE IN
-
-
Slide moves inside.
-
-
-
Exit to main menu.
FOCUS
-
-
Enter focus servo test.
REMOTE CONTROL
ERASE THE
KEY TEST
EEPROM
PROGRAM
Button pressed?
REMARK
R-C Key
DISPLAY
Display shows "EP CLR"
POWER
12
CD
63
TUNER
63
PROGRAM
Button pressed?
AUX
63
OPEN*CLOSE
45
DBB
70
PROG
36
REPEAT
29
SHUFFLE
26
PLAY
53
VOL+
16
VOL-
17
13
MUTE
15
RDS * NEWS
52
50
PREVIOUS(
)
33
NEXT (
)
32
STOP
"VER XXX"
Exit to main menu
42
CLOCK SET
TIMER
89
SLEEP
38
Note : In Key test mode, if a key on the remote control is pressed,
the display shows its corresponding code in track area.
3-1
DISPLAY
TEST
N
N
VOLUME-
Button pressed?
Y
Y
Display shows all display
segments and switch all
LEDs on.
N
N
VOLUME-
Button pressed?
Y
Y
Display shows alternate
display segments & switch
alternate LEDs on.
N
STOP
Button pressed?
Y