Download Print this page

Sony PVM-L2300 Manual page 17

Lcd broadcast monitor
Hide thumbs Also See for PVM-L2300:

Advertisement

Specifications
BKM-250TG
INPUT/OUTPUT
Digital component signals Sampling frequency
3G-SDI: Y/Cb/Cr: 148.5 MHz/74.25 MHz/74.25 MHz,
Serial Digital Interface
HD-SDI: Y/Cb/Cr: 74.25 MHz/37.125 MHz/37.125 MHz,
SD-SDI: Y/Cb/Cr: 13.5 MHz/6.75 MHz/6.75 MHz
BNC x 1, Output signal amplitude: 800 mVp-p ± 10 %
Monitor Out
3G-SDI: 50 m (approx. 164 ft) max. (When using 5C-FB
HD-SDI: 100 m (approx. 328 ft) max. (When using 5C-FB
Transmission Distance
SD-SDI:200 m (approx. 656 ft) max. (When using 5C-2V
GENERAL
Voltage
Power Consumption
Operating Temperature
(Optimum temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
Mass
Supplied Accessories
BKM-243HS
INPUT/OUTPUT
Sampling Frequency: SD-SDI: Y/R-Y/B-Y: 13.5 MHz,
Serial Digital Interface
Monitor Out
Output signal amplitude: 800 mVp-p ± 10 %
SD-SDI: 200 m (approx. 656 ft) max. (when using
Transmission Distance
HD-SDI: 100 m (approx. 328 ft) max. (when using
GENERAL
Voltage
Power Consumption
0 °C to 35 °C (32 °F to 95 °F) (Recommended
Operating Temperature
operation temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
Mass
Supplied Accessories
BKM-227W
INPUT/OUTPUT
Composite Input
Y/C Input
C: 0.286 Vp-p ± 3 dB (NTSC burst signal level),
0.3 Vp-p ± 3 dB (PAL burst signal level) (SECAM, PAL-M)
BNC x 1, Loop-through, with 75 Ω automatic termination
Monitor Out
Loop-through, with 75 Ω automatic termination
GENERAL
Voltage
Power Consumption
0 °C to 35 °C (32 °F to 95 °F) (Recommended
Operating Temperature
operation temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
Mass
Supplied Accessories
BNC x 2,
G/B/R: 148.5 MHz/148.5 MHz/148.5 MHz
Output impedance: 75 Ω unbalanced
coaxial cables (Fujikura. Inc.) or equivalent.)
coaxial cables (Fujikura. Inc.) or equivalent.)
coaxial cables (Fujikura. Inc.) or equivalent.)
+5 V, +3.3 V (supplied from the main unit)
Approx. 4 W
0 °C to 35 °C (32 °F to 95 °F)
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-20 °C to +60 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Approx. 270 g (9.5 oz)
Operating Instructions (1)
BNC x 2, Digital Component Signals
HD-SDI: Y/Pb/Pr: 74.25 MHz
Quantization: 10 bits/sample
BNC x 1,
Output impedance: 75 Ω unbalanced
5C-2V coaxial calbes (Fujikura) or equivalent)
5C-FB coaxial cables (Fujikura) or equivalent)
+3.3 V (supplied from the main unit)
Approx. 2 W
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-10 °C to 40 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Approx. 250 g (9 oz)
Operating Instructions (1)
BNC x 1,
1 Vp-p ± 3 dB sync negative
4-pin mini DIN x 1
Y: 1 Vp-p ± 3 dB sync negative
4-pin mini DIN x 1,
+3.3 V (supplied from the main unit)
Approx. 1.8 W
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-10 °C to 40 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Approx. 240 g (8 oz)
Operating Instructions (1)
BKM-244CC
INPUT/OUTPUT
Serial Digital Interface
Sampling Frequency: SD-SDI: Y/R-Y/B-Y: 13.5 MHz,
Monitor Out
Output signal amplitude: 800 mVp-p ± 10 %
SD-SDI: 200 m (approx. 656 ft) max. (when using
5C-2V coaxial calbes (Fujikura) or equivalent)
Transmission Distance
HD-SDI: 100 m (approx. 328 ft) max. (when using
5C-FB coaxial cables (Fujikura) or equivalent)
GENERAL
Voltage
+5 V, +3.3 V (supplied from the main unit)
Power Consumption
0 °C to 35 °C (32 °F to 95 °F) (Recommended
Operating Temperature
operation temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Mass
Supplied Accessories
BKM-229X
INPUT/OUTPUT
0.7 Vp-p ± 3 dB (Sync on Green, 0.3 Vp-p sync negative)
BNC x 3
0.3 to 4 Vp-p ± bipolarity ternary or negative polarity binary
External Sync Input
Loop-through, with 75 Ω automatic termination
GENERAL
Voltage
+3.3 V, +5 V (supplied from the main unit)
Power Consumption
0 °C to 35 °C (32 °F to 95 °F) (Recommended
Operating Temperature
operation temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Mass
Supplied Accessories
BKM-220D
INPUT/OUTPUT
Serial Digital Interface
Sampling Frequency: Y/R-Y/B-Y: 13.5 MHz
Monitor Out
Output signal amplitude: 800 mVp-p ±10 %
200 m (approx. 656 ft) max. (when using
Transmission Distance
5C-2V coaxial calbes (Fujikura) or equivalent)
GENERAL
Voltage
Power Consumption
0 °C to 35 °C (68 °F to 95 °F) (Recommended
Operating Temperature
operation temperature 20 °C to 30 °C (68 °F to 86 °F))
Operating Humidity
Operating Pressure
Storage and Trans. Temperature
Storage and Trans. Humidity
Storage and Trans. Pressure
Dimensions (W x H x D)
100 x 20 x 162 mm (4 x 13/16 x 6 1/2 inches)
Mass
Supplied Accessories
BNC x 2,
Digital Component Signals
HD-SDI: Y/Pb/Pr: 74.25 MHz
Quantization: 10 bits/sample
BNC x 1,
Output impedance: 75 Ω unbalanced
Approx. 3.8 W
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-10 °C to 40 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
Approx. 250 g (9 oz)
Operating Instructions (1)
RGB Input
Component Input
0.7 Vp-p ± 3 dB
BNC x 1,
4-pin mini DIN x 1,
Approx. 4 W
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-10 °C to 40 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
Approx. 250 g (9 oz)
Operating Instructions (1)
BNC x 2,
Digital Component Signals
Quantization: 10 bits/sample
BNC x 1,
Output impedance: 75 Ω unbalanced
+5 V (supplied from the main unit)
Approx. 1.5 W
0 % to 90 % (no condensation)
700 hPa to 1060 hPa
-10 °C to 40 °C (14 °F to 104 °F)
0 % to 90 %
700 hPa to 1060 hPa
Approx. 250 g (9 oz)