Summary of Contents for Pocasa H6KS

  • Page 1 H series online UPS LED 6/10KS(L), 10,15,20KL3/1 ’ ’ ’ PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn...
  • Page 2 The address of service center has been detailed on the warranty card. Note: POCASA reserves the right to make changes to product described in this manual at any time and without notice for reasons of improvement.
  • Page 3: Table Of Contents

    Contents 1. Brief introduction-------------------------------------------------------------------------------------------------------------------3 1.1. Technology introduction----------------------------------------------------------------------------------------------------3 1.2. System and model description--------------------------------------------------------------------------------------------4 1.3. Description of commonly used symbols--------------------------------------------------------------------------------4 1.4. Appearance--------------------------------------------------------------------------------------------------------------------5 1.5. Product specification and performance---------------------------------------------------------------------------------6 2. Installation---------------------------------------------------------------------------------------------------------------------------8 2.1. Unpacking and inspection--------------------------------------------------------------------------------------------------8 2.2. Safety notes--------------------------------------------------------------------------------------------------------------------9 2.3. The description of front panel and display lamp--------------------------------------------------------------------10 2.4.
  • Page 4: Brief Introduction

    1. Brief introduction 1.1. Technology introduction ● This UPS is a sophisticated piece of equipment with 16 bit Microprocessor and advanced software programming technology, high frequency SPWM is created to control the inverter of UPS. This simplifies the control circuit, enhances the stability of UPS, also enables the UPS to have enhanced real-time performance that makes UPS respond the variety of external environment rapidly and insure that the control circuit is compact and reliable.
  • Page 5: System And Model Description

    This manual is applicable to the following models: 1) The H6KS is model with inbuilt battery, hereinafter called 6KS; 2) The H6KL is a long backup time model, which is able to connect with the external battery bank, hereinafter-called 6KL;...
  • Page 6: Appearance

    The following symbols will be used in this manual and may appear during the course of your practical applications. Therefore, all users should be familiar with them and understand their meanings. Notation and Explanation Notation Explanation Alert you to pay special attention Caution of high voltage ︱...
  • Page 7: Product Specification And Performance

    Back view of 6KL Back view of 10KL/three phase 10KL Back view of three phase 15KL/three phase 20KL 1.5. Product specification and performance 1.5.1. General specification (standard models) Model H6KS H6KL H10KS H10KL Power rating 6KVA/4.2KW 6KVA/4.2KW 10KVA/7KW 10KVA/7KW Frequency(Hz)
  • Page 8 60A Max 80A Max Output Voltage 220VAC/230VAC 220VAC/230VAC 220VAC/230VAC Dimension(W×D×H)mm 260×570×717 260×570×717 260×570×717 Net weight(Kg) 1.5.2. Dimension & weight for UPS with galvanic isolation Model H6KS H6KL H10KS H10KL Power rating 6KVA/4.2KW 6KVA/4.2KW 10KVA/7KW 10KVA/7KW Dimension(W×D×H)mm 700×430x845 700×430x845 700×430x845 700×430x845...
  • Page 9: Installation

    Altitude(M) 1000 1500 2000 2500 3000 3500 4000 4500 5000 Derating power 100% 2. Installation 2.1. Unpacking and inspection 1). Unpack the packaging and check the package contents. The shipping package contains: A UPS A user manual A communication cable A battery cable(for “L”...
  • Page 10: The Description Of Front Panel And Display Lamp

    2.3. The description of front panel and display lamp Power ON/OFF: to turn on the UPS simply by pressing the “ON” button on the front panel ● continuously for 1 second. Press the “OFF” button on the front panel continuously for 1 second to turn off the UPS.
  • Page 11: Input And Output Power Chords And Protective Earth Ground Installation

    1) Open the terminal block cover located on the rear panel of the UPS, please refer to the appearance diagram. 2) For H6KS(L) UPS, it is recommended to select the UL 1015 10AWG(6mm )wire or other insulated wire which complies with AWG standard for the UPS input and output wirings.
  • Page 12 UPS, as its start-up power consumption is too big when it is started. Input and output terminal block wiring diagram of H6KS(L)/H10KS(L) Important notes: if the UPS is used in single mode, JP1 and JP2 must be connected by 10AWG (6mm );...
  • Page 13: Operating Procedure For Connecting The Long Backup Time Model Ups With The External Battery

    Input and output terminal block wiring diagram of three-phase 15KS/20KS Important notes: if the UPS is used in single mode, JP1 and JP2 must be connected by 6AWG (25mm ); if the UPS is used in parallel mode, the Jumper between JP1 and JP2 must be removed. 2.5.
  • Page 14: Parallel Operation

    battery socket of the UPS. Do not attempt to connect any loads to the UPS now. You should connect the input power wire to the right position first, and then set the breaker of the battery pack in the ON position. After that set the input breaker in the ON position, The UPS begins to charge the battery packs at the time.
  • Page 15: Operation And Operating Mode

    When the distance between the UPSs in parallel and the breaker panel is greater than 20 meters, the difference between the wires of input & output of the UPS is required to be less than 10%. 2.6.3. Operation and maintenance 1) To perform the general operation, follow the stand-alone operating requirement;...
  • Page 16 4) When being powered on, the UPS will perform self-diagnosis, with the load/battery level LEDs turned on and then off one after another in ascending order. A few seconds later, the INV LED is turned on, the UPS is already running in utility power mode. If the utility power is abnormal, the UPS will operate in battery mode without output interruption of the UPS.
  • Page 17: Operating Mode

    3.2. Operating mode 3.2.1. Utility mode The display panel in utility power mode is shown in the following diagram, the utility power LED and the INV LED are turned on, The load level LEDs will be turned on in accordance with the load capacity connected.
  • Page 18 Fig 3-2: Battery mode diagram 2) When the battery capacity decreases, the number of the battery capacity LEDs turned on will be reduced. If the battery voltage descends to the alarm level, the buzzer will beep once every second to remind the users of in sufficient battery capacity and the UPS is soon going to shut down automatically.
  • Page 19 The backup time of standard model may vary from different models and load level, please refer to the following: Load capacity Load capacity H6KS(L) backup time curve H10KS(L) backup time curve 3.2.6. Communication port Intelligent slot This series is equipped with an intelligent slot for web power (optional accessory) or other optional card to achieve remote management of the UPS through internet/intranet.
  • Page 20 DB-9 pin assignment: Pin number Function description Input Output RS232 interface Ground Optional AS400 interface This optional AS400 card provides dry contact closure signal “OPEN” or “CLOSE”. Following are the pin assignment and the descriptions of AS400 card: PIN1:UPS failure (normally open, active close) PIN2:Summary PIN3:Ground PIN4:Remote shutdown...
  • Page 21: Notes For Battery Disposal And Battery Replacement

    4. Notes for battery disposal and battery replacement ● The battery of standard unit is of valve regulated, maintenance free. It can attain expectant life only by keeping frequent charging. Regardless of UPS on or off when UPS connects to utility power, the battery is charged all the time and UPS offers protection for over-charge and over-discharge.
  • Page 22: Troubles Shooting

    7. Batteries contain hazardous voltage and current. Battery maintenance such as the battery replacement must be carried out by qualified personnel who are knowledgeable about batteries. No other persons should handle the batteries. 5. Troubles shooting The following messages are the messages that users would find on UPS when it meets some problem, with the use of such messages, users can know where the problems are and how to deal with such problems.
  • Page 23 Bypass breaker in “OFF” Set the bypass breaker in “ON” position The utility power is normal, but the UPS can not turn in position line mode Battery discharging time Battery not yet been fully Keep UPS connected to utility power diminishes charge persistently for more than 10 hours to...
  • Page 24: Appendix: The Corresponding Form Of The Led Display

    Appendix: The corresponding form of the LED display LED display Operating state Alarm warning 0~35% ☆ ☆ ☆ None Load capacity 36~55% ☆ ☆ ☆ ☆ None Load capacity Utility 56~75% ☆ ☆ ☆ ☆ ☆ power None Load capacity mode 76~95% ☆...
  • Page 25: Appendix 2: Emc Grade Standards

    Battery voltage ↑ ↑ ↑ ↑ ↑ ☆ ☆ ★ ↑ abnormal Continuously ☆ ☆ ☆ BAT SCR failed beep Continuously ☆ ☆ ☆ ☆ ☆ Fan abnormal beep Sustained ☆ ☆ ☆ ☆ ☆ Bypass STS failed beep Sustained ☆...