Direct Vent Installation—Horizontal Installations
Refer to the appropriate vent table for proper pipe size, vent
length and the number of elbows allowed, and air intake
length and the number of elbows allowed.
Refer to "Materials" in "Plan Vent System" for the proper
venting material.
Do not install the inlet air restrictor plate in any direct vent
installation. The inlet air restrictor plate (see "Inlet Air
Restrictor Plate" in "Venting Requirements") supplied with
this furnace is to be used only in nondirect vent applications.
The flue pipe screen, designed to keep objects out of the flue
pipe (see "Flue Pipe Screen" in "Venting Requirements"),
should be installed at the termination of the flue pipe.
Direct Vent—Horizontal (Horizontal Venting—Horizontal
Right to Left)
A B
A. Drain tee (in kit)
B. 3" (7.6 cm) long piece of 2" (5.1 cm) diameter pipe
Direct Vent—Horizontal (Horizontal Venting—Horizontal
Left to Right)
A. 3" (7.6 cm) long piece of 2"
(5.1 cm) diameter pipe
B. Drain tee (in kit)
C. 18" (45.7 cm)
14
A
B
C
D
E
D. 6" (15.2 cm)
E. 12" (30.5 cm) minimum clearance.
Adjust height to expected snow level
based on local conditions.
NOTE: Do not place an additional flue pipe screen in the
intake termination because the air intake may freeze shut.
For proper operation, the vent and air intake pipe must be
installed in the same pressure zone. Therefore, in horizontal
venting applications they must be on the same side of the
house within the parameters as shown.
NOTE: The 18" (45.7 cm) dimension shown below is the
minimum recommended height for extremely cold areas. In
these areas, moisture in the flue gases may condense and
freeze on the air intake if this height is reduced. In milder
climates, this may be reduced to a minimum of 6" (15.2 cm).
Height may be increased as needed provided total length of
pipe to furnace is not exceeded.
Direct Vent—Horizontal (Horizontal Venting—Horizontal
Left to Right Alternate Venting for Low Clearance
Installations)
A. 3" (7.6 cm) long piece of 2"
(5.1 cm) diameter pipe
B. 2 each of 2" (5.1 cm) 90º
street elbows
C. Drain tee (in kit)
A
B
C
D
E
F
D. 18" (45.7 cm)
E. 6" (15.2 cm)
F. 12" (30.5 cm) minimum clearance.
Adjust height to expected snow level
based on local conditions.