Maintaining and Troubleshooting the HP ProLiant DL360 G7 Server
Task
Reference
MSG: Removal and
replacement procedures:
• PCI riser board
assembly
• Expansion boards
• PCIe riser board
MSG: Removal and
replacement procedures >
Fan module
MSG: Removal and
replacement procedures >
DIMMs
MSG: Removal and
replacement procedures >
BBWC battery pack or
FBWC capacitor pack
Replacing internal components
Avaya
recommendation
Mark any cables
connected to the NIC
and reconnect to the
same ports after the NIC
is replaced.
The NIC requires a half-
HT faceplate. You might
need to remove the full
faceplate and replace it
with the half faceplate,
which requires a
crosshatch (Phillips)
screwdriver.
Note:
If adding a NICs:
populate PCI Slot 1
first, followed by Slot
2.
Refer to the Systems
Insight Display LEDs to
identify the defective fan.
Refer to the Systems
Insight Display LEDs to
identify the defective
DIMM.
Caution:
When removing the
air baffle, ensure that
the RAID battery does
not fall out of its
compartment in the
baffle.
Caution:
Refer to the
information on the top
of the air baffle and
inside cover for
correct DIMM
placement.
Caution:
Consult the internal
label with directions
for removing the air
baffle. Be careful that
the RAID battery does
November 2010