MAIN PCB
1) Items to be adjusted:
Item
Vop voltage setting
2) Adjustment and Test Point Locations
Test point
3) Equipment connection/Procedure
Input
Input
Connection
Point
Eye
37°
LCD

ADJUSTMENT

Voltmeter
(TOP VIEW)
Vop voltage setting
Set
Output
R62
Input
Output
Adjust
Signal
Connection
VR1
Watching the LCD at a 37° angle to the horizontal, adjust Vop
voltage so that unenergized segments are seen dimly.
— 7 —
Measuring Instrument
Voltmeter
Output
Point
Voltmeter
R62
Adjust for
Adjust for 4.4 ±0.1 V reading
on voltmeter.
Make fine adjustment accord-
ing to the next instruction.