Use each module in an environment as specified in the "general
specification" in the CPU module User's Manual. Usage of the module
outside the general specification range may cause electric shock, fire,
malfunction, product damage or deterioration.
Do not have control cables and communication cables bundled with or
placed near by the main circuit and/or power cables. It may cause
malfunction due to noise interference. Wire those cables at least
100mm(3.94 inch) away from the main circuit and/or power cables.
Do not directly touch the module's conductive parts.
Doing so could cause malfunction or trouble in the module.
Tighten the module securely using DIN rail or installation screws within the
specified torque range.
Loose terminal screws may cause falling, short circuit or erroneous
operation.
If the terminal screws are too tight, it may cause falling or short circuit due
to damage of the screws.
Fix terminal screws securely with the specified torque.
Loose terminal screws may cause short circuit or erroneous operation.
If the terminal screws are too tight, it may cause falling, short circuit or
erroneous operation due to damage of the screws or module.
Be sure to ground the FG terminal to the class-D (class 3) or higher
sequencer dedicated grounding conductor.
Otherwise there will be an electric shock or misoperation.
Terminal screws which are not to be used must be tightened always.
Otherwise there will be a danger of short circuit against the bare solderless
terminals.
Perform correct wiring for the module according to the product's rated
voltage and terminal arrangement. Connecting to a power supply different
from the rating or mis-wiring may cause fire and/or trouble.
Make sure foreign objects do not get inside the module, such as dirt and
wire chips.
It may cause fire, trouble or malfunction.
Be sure to fix the communication and power cables that are connected to
the module in place, either by running them through a duct or by using
clamps.
If the cables are not fixed in one of these ways, dispersion, movement, or
careless pulling of the cables may cause damage to the module or cables,
or malfunction due to cable contact faults.
When removing the communication cable or power supply cable from the
module, do not pull the cable. When removing the cable with a connector,
hold the connector on the side that is connected to the module.
When removing the cable connected to the terminal block, first loosen the
screws on the part that is connected to the terminal block.
Pulling the cable that is still connected to the module may cause
malfunction or damage to the module or cable.
CAUTION