LG ARUN Series Service Manual page 14

Multi v plus ii system outdoor unit r410a
Hide thumbs Also See for ARUN Series:
Table of Contents

Advertisement

Specification
HP(Equivalent horsepower)
Model
Capacity
Cooling
Power Input
Cooling
Current
Cooling
COP
Cooling
Casing Color
Heat Exchanger
Compressor
Type
Piston Displacement
Number of Revolution
Motor OutputÅ~Number
Starting Method
Oil Type
Oil Charge
Fan
Type
Motor Output x Number
Air Flow Rate(High)
Drive
Discharge
Pipe Connctions
Liquid Pipes
Gas Pipes
Dimensions(W x H x D)
Net Weight
Transmission Cable
Refigerant
Refigerant name
Charge
Control
Power Supply
Notes:
1. Capacities are based on the following conditions:
Cooling * Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
* Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
* Interconnecting Piping Length 7.5m(24.6ft)
* Level Difference of Zero
Heating * Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
* Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
* Interconnecting Piping Length 7.5m(24.6ft)
* Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Unit
30
Combination Unit
ARUV300BT2(E)
Independent Unit
ARUV100BT2(E)
ARUV100BT2(E)
ARUV100BT2(E)
kW
84
kcal/h
72200
Btu/h
286600
kW
23.4
A
84.9
3.59
Warm Gray
Gold fin
DC Scroll
cm
3
/rev
(38.3+59.8)*3
r.p.m
(3,600+3,500)x3
W
(4,130+5,280)x3
Direct On Line
FVC68D(PVE)
L
5600*3
Propeller fan
W
350 x 6
cmm
570
cfm
20100
DC INVERTER
Side / Top
TOP
mm(inch)
19.05(3/4)
mm(inch)
34.9(1 3/8)
mm
(1280x1607x730)*2 (1280x1607x730)*2
inch
(50.4x63.3x28.7)*2
kg
285+285
Ibs
628+628
CVV-SB 1.25x2C
R410A
kg
8+8
EEV
Ø,V,Hz
3, 220, 60
- 14 -
Cooling (220V)
32
34
ARUV320BT2(E)
ARUV340BT2(E)
ARUV120BT2(E)
ARUV120BT2(E)
ARUV100BT2(E)
ARUV120BT2(E)
ARUV100BT2(E)
ARUV100BT2(E)
89.6
95.2
77,100
81,900
305,700
324,800
26.40
29.40
89.20
93.50
3.39
3.24
Warm Gray
Warm Gray
Gold fin
Gold fin
DC Scroll
DC Scroll
(38.3+59.8)*3
(38.3+59.8)*3
(3,600+3,500)x3
(3,600+3,500)x3
(4,130+5,280)x3
(4,130+5,280)x3
Direct On Line
Direct On Line
FVC68D(PVE)
FVC68D(PVE)
5600*3
5600*3
Propeller fan
Propeller fan
350 x 6
350 x 6
570
570
20,100
20,100
DC INVERTER
DC INVERTER
TOP
TOP
19.05(3/4)
19.05(3/4)
34.9(1 3/8)
34.9(1 3/8)
(1280x1607x730)*2
(50.4x63.3x28.7)*2
(50.4x63.3x28.7)*2
285+285
285+285
628+628
628+628
CVV-SB 1.25x2C
CVV-SB 1.25x2C
R410A
R410A
8+8
8+8
EEV
EEV
3, 220, 60
3, 220, 60
E : Anti-Corrosion Model
36
ARUV360BT2(E)
ARUV120BT2(E)
ARUV120BT2(E)
ARUV120BT2(E)
100.8
86,700
343,900
32.40
97.80
3.11
Warm Gray
Gold fin
DC Scroll
(38.3+59.8)*3
(3,600+3,500)x3
(4,130+5,280)x3
Direct On Line
FVC68D(PVE)
5600*3
Propeller fan
350 x 6
570
20,100
DC INVERTER
TOP
19.05(3/4)
41.3(1 5/8)
(1280x1607x730)*2
(50.4x63.3x28.7)*2
285+285
628+628
CVV-SB 1.25x2C
R410A
8+8
EEV
3, 220, 60
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aruv series

Table of Contents