1.1 INTRODUCTION First of all, thank you for purchasing R3G Series – 2 + 1 Redundant power supply, the R3G is a 2+1, Hot-swappable/Hot-pluggable, Redundant power supply set, it consists of: (1) complete metal frame (nickel-plated) (2) 2 + 1 compact size power modules...
1.2 PACKING Your R3G box package should consist of the following: (A) R3G *1 (B) Accessory pack (included one holding bracket for shipment)*1 (C) Products’ manual *1 1.3 MODEL DESIGNATION Model number identification: R3G – 6650P --- 2 + 1 Redundant Power Supply for 3 U (AC Input) --- for 6 DC outputs (5V/12V/-5V/-12V/3.3V/5VSB) for ATX12V / EPS12V Spec.
1.4 FEATURES R3G Series --- 2 + 1 Redundant power supply ( w/PFC ) 2+1, Hot swappable, Hot pluggable, AC Input, 650 W output Compact size, 650W + 350W, PFC, ATX12V / EPS12V outputs True Redundant design (Passive backplane) All circuit been designed in the power module...
Page 11
INPUT CHARACTERISTICS: R3G-6650P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 9.0 / 5.0 A FOR 115 / 230 VAC INRUSH CURRENT: 80A / 100A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION...
Page 12
1.8 INSTALLATION & TESTING Turn off (Remote off) the on/off switch. Mount the power supply in the system chassis using the proper mounting tool, the mounting holes in the power supply should match up with those in the case. Attach the connectors to the M/B by following the M/B instructions, there are various on connectors / pinouts in both power supply and M/B.
Page 13
If everything works out fine, then turn off (remote off) the power system, now put back the cover of the case and tighten with the screws which you have retained earlier. Now you have completed the installation of the R3G redundant power supply system.
Page 14
E) Check the LED of the power module lit Green. F) Check the LED which indicates the total power system status, that should be from twinkle to Green. G) Tighten the screws of bracket which hold the power modules to fix it. H) If you want to test this new power module in simulating defective situation.
1.11 TROUBLE SHOOTING If you have followed these directions correctly, there should be no problem occurred. Some common symptoms are: the system doesn’t work, buzzer sound, work for a very short period, etc., please try the following steps to verify and correct it: 1.
Page 16
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP. POWER DIVISION HEADQUARTERS 10F, NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY, TAIPEI HSIEN, TAIWAN, R.O.C. TEL: 886-2-29188512 FAX: 886-2-29134969 WEB SITE: http://www.zippy.com.tw E-mail:power@zippy.com.tw USA OFFICE U.S. East (Atlantic) 11 Melanie Lane, Unit 1B East Hanover, NJ 07936 TEL:1-973-463-9499 FAX:1-973-453-8014 E-mail:edward@zippy.com...
Need help?
Do you have a question about the R3G SERIES and is the answer not in the manual?