Table Of Contents; Specifications; Operation; Transporting The Ultimate 340 - Jon-Don Ultimate 340 Owner's Manual

Table of Contents

Advertisement

Table of Contents

Introduction ............................................................................. 1
1. Specifications .................................................................. 2
2. Operation ......................................................................... 2
2.1 Transporting the Ultimate 340 ................................. 2
2.2 Location ..................................................................... 2
2.3 Electrical Requirements ............................................ 3
2.4 Condensate Removal ................................................ 3
2.5 Ducting ....................................................................... 3
2.6 Power Switch ............................................................. 3
2.7 Pump Purge Switch ................................................... 3
2.8 Hour Meter ................................................................. 3
2.9 Defrost Control Adjustment ...................................... 3
2.10 Hours Button ........................................................... 3
2.11 Defrost Light ............................................................ 3
2.12 Low Pressure Control .............................................. 3
3. Maintenance .................................................................... 3
3.1 Air Filter ...................................................................... 3
3.2 Storage ....................................................................... 4
4. Service .............................................................................. 4
4.1 Warranty ..................................................................... 4
4.2 Technical Description ................................................ 4
4.3 Troubleshooting ......................................................... 4
4.4 Air Mover Replacement ............................................. 5
4.5 Thermistor Replacement .......................................... 5
4.6 Condensate Pump Replacement ............................. 5
4.7 Refrigerant Charging ................................................. 6
4.8 Compressor/Capacitor Replacement ...................... 6
4.9 Gravity Drain Option .................................................. 6
4.10 Relay......................................................................... 6
5. Wiring Diagram ............................................................... 7
6. Service Parts List ............................................................. 8
7.
Warranty .........................................................................10
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer's Name ___________________________________
Toll-Free 1-800-556-6366
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your Ultimate 340 dehumidifier.

1 Specifications

Part No.
OE-ULT340-EA
110-120 Vac, 10 amps
Power
Water
145 pints/day @ AHAM (80°F, 60%)
Removal
Refrigerant
1 lbs. 10 oz R410a
Charge
340 CFM
Blower
Internal Condensate Pump with 20' lift,
30' vinyl hose
Operating
33°F to 105°F
Range
Filters
16" x 20" x 2" Pleated Media MERV-11
Duct
Intake - 12" Flex-Duct
Exhaust - 10" Lay-Flat
Options
Five years;
Warranty
First year 100% of Parts and Labor
Second-fifth year 100% of Parts of sealed
refrigeration system.
Dimensions Width 20", Height 40-1/4", Depth 21-1/4"
130 lbs.
Weight
Patent
D570,988

2 Operation

2.1 Transporting the Ultimate 340

The Ultimate 340 must always be upright when transported
by vehicle. It may be tipped on to its handle and back for
loading and moving by hand.

2.2 Location

Note the following precautions when locating the Ultimate
340:
• It is designed to be used INDOORS ONLY.
• If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
• DO NOT use the Ultimate 340 as a bench or table.
• It must always be used in the upright position.
• The air inlet on top & the side outlet must be at least
1 foot from walls and other obstructions to air flow.