Maintaining The Inteli-Power Marine Converter/Charger; Trouble Shooting Guide; Sample Wiring Diagrams For Series/Parallel Connections - Progressive Dynamics PD2020 Owner's Manual

Electronic marine converter/charger
Table of Contents

Advertisement

7.
MAINTAINING THE INTELI-POWER MARINE
CONVERTER/CHARGER
7.1
No adjustments or maintenance is required for the INTELI-POWER
MARINE converter other than periodically checking all electrical
connections for tightness by a qualified service person.
Check battery water level frequently, especially if boat is
at dock for extended periods of time. Low water levels
will damage batteries!
TROUBLESHOOTING THE INTELI-POWER MARINE CONVERTER/CHARGER

TROUBLE SHOOTING GUIDE

PROBLEM
POSSIBLE CAUSES
1. No Output
120 VAC supply not
connected
Internal Fuse(s) Blown
Short Circuit
Unit has shutdown due
to overheating
Unit has shutdown due
to over voltage
2. Internal Fuse(s)
Reverse Battery Hook
Blown
Up
3. Converter
Compartment gets too
cycles on & off
hot
4. Low Output
Excessive Load for
Converter
Input Voltage not
between 105-130 VAC
Bad Battery Cell(s)
CAUTION
ACTION
Connect power supply
Check AC distribution panel for
proper operation
Check for Reverse Polarity
Replace Fuse(s) with same type
and rating
Trace Vessel Circuits for possible
fault
Check air flow
Allow unit to cool
Check input voltage
Converter will shut down if the
input voltage exceeds 132 Volts
Correct Input Voltage
Correct Hook up and replace
Fuse(s) with same type and rating
Check air flow to the converter
Improve Ventilation to the
compartment
Reduce load requirements or
Install Larger Converter
Correct input supply voltage
Replace Battery
-11-

SAMPLE WIRING DIAGRAMS FOR SERIES/PARALLEL CONNECTIONS.

The Inteli-Power chargers can be wired in series to provide a 24 volt charging system.
They can also be wired in parallel to provide additional charge current.
Parallel Connection:
Wiring the Inteli-power chargers as shown below will provide additional charging
current to the 12 volt house battery system and eliminates the need to install additional
chargers for the engine, generator and the 12 volt bow thruster batteries.
The Parallel system shown above using PD2050 Chargers can provide a maximum of
100 amps to recharge the house battery system. It can also provide up to 50 amps to
charge the engine, bow thruster or generator batteries if the house batteries are fully
charged.
-12-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd2030Pd2050Pd2040Pd2060Pd2080

Table of Contents