Kenwood KDC-4551UB/455UW Service Manual page 5

Table of Contents

Advertisement

Status
Adjustment not
E
implemented
RDS Specifi ed data
R
D
reception
Operations
Operation
TUNER IC
ACCENT
display
4
Preset operation
BAND switch
BAND
operation
S meter voltage
SEARCH
judgment display
Shift to TUNER
■DISP
setting mode
TUNER Setting Adjustment Mode
1. Operation (Operation after performance of above-mentioned "Shift to TUNER setting mode" item)
Operation
AUTO Adjustment
■BAND
(Toggle)
Mode
2. Operations in AUTO Adjustment Mode
Operation
VOL PUSH
Adjustment start
3. Status display during adjustment
Status
Adjustment success
A
D
Adjustment failure
A
D
TEST MODE
Display content
R
R
A
9
S
T
E
S
T
Display content
A
T
O
M
R
D
S
F
M
1
3
A
F
M
1
3
A
S
M
T
R
S
M
T
R
S
M
T
R
Display content
A
S
x
x
Display content
A
S
x
x
Display content
J
O
K
J
N
G
KDC-4551UB/455UW/4651URY
KDC-U449/U5049
For models that TUNER adjustment is necessary but not done
(adjustment value: 0x00 or 0xFF), the following TUNER Test
7 . 9
A
Mode functions are valid ("∗ERR∗" display is continuing).
Display "∗ERR∗" blinks with 250ms interval.
Turn OFF P-CON forcibly if PS=RDS TEST is received.
P-CON recovers with Power OFF/ON.
Display TUNER IC version
✳ Display content is assigned by Tuner Development G.
Switch to either 98.3 (except for J type)
9
7 . 9
A
Execute Band Switch as shown in the following table
9
7 . 9
A
every time Band key is pressed in each type.
S meter value xx: Current S meter value
x
x : O
K
Determination result OK: Within S meter voltage spec
x
x : N
G
x
x : –
Transit to TUNER setting adjustment mode after switching
to 98.3MHz
Frequency: 98.3MHz, Modulation frequency: 1kHz,
Modulation mode: MONO, Modulation: OFF,
Deviation: 40kHz, ANT input level: 34dBμV
Select TUNER adjustment method (A: AUTO) us-
ing BAND key.
S-xx: Current S meter value (Hex)
L
x
x
L-xx: Level offset value (Hex)
✳ In case that the level offset value is not ad-
justed (0xFF or 0x00), display "– –".
Start Adjustment (Start Auto adjustment, and
transit to Success/Failure display depending on
L
x
x
the adjustment result)
When the adjustment value write-in to E2PROM (IC771 on X34)
: x
x
has been completed.
When the adjustment value write-in to E2PROM (IC771 on X34)
has failed.
Details
Details
NG: Out of S meter voltage spec
– – : No LEVEL OFFSET adjustment
Details
Details
Details
xx: Level offset value (HEX)
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-u449/u5049Kdc-4651ury

Table of Contents