Page 2
Dear Customer, If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high per- formance and will remain efficient for many years to come. CONTENTS RECOMMENDATIONS AND SUGGESTIONS CHARACTERISTICS INSTALLATION MAINTENANCE...
RECOMMENDATIONS AND SUGGESTIONS INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. • The minimum safety distance between the cooker top and the extractor hood is 650 mm. • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
INSTALLATION Wall drilling and bracket fixing 7.2.1 Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. •...
Page 6
Mounting the hood body • Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. • Hook the hood body onto the screws 12a • Fully tighten support screws 12a • Adjust screws Vr to level the hood body. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe...
Page 7
ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Control Panel The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. FUNCTIONS 0/1 Light Turns lighting on and off. 0/1 Motor First speed. When pressed for about 1 seconds the motor is switched off. Speed Second speed.
REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type. • Do not place the remote control near to heat sources. • Used batteries must be disposed of in the proper manner MAINTENANCE Grease filters...
Page 10
Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER Enabling the alarm signal • In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. • Turn the Lights and the suction Motor off. •...
Page 12
Dir. 89/336/CEE 73/23/CEE 93/68/CEE The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
Need help?
Do you have a question about the DKC 5030 and is the answer not in the manual?