MO DE L NAME
ADJ US T ME NT
IT E M
ADJ US T ME NT
P O S IT IO N
C O NT R O L
P R E -ADJ US T
O P T IO N S E T UP , B US S E T UP
R E Q UIR E ME NT
NO S IG NAL (R AS T E R ) C O NDIT IO N
C O NT E NT
INP UT
AC 220
C O NDIT IO N
O UT P UT
C O NF IR MAT IO N O N C R T DIS P L AY (AUT O ), IC 801 P IN 2 V O L T AG E (MANUAL ).
(AT S E L F ADJ US T ME NT MO DE )
1)G O INT O S E R V IC E MO DE ,B Y S E L E C T ING T HE S E R V IC E DAT A V 10
2)P R E S S T HE R /C F O R AUT O P IF -V C O K E Y , O S D AP P E AR "O K " AT S C R E E N
3)IF AP P E AR "NG " P L S R E P E AT S T E P 2
(AT MANUAL ADJ US T ME NT MO DE )
1)G O INT O S E R V IC E MO DE , B Y S E L E C T ING T HE S E R V IC E DAT A V 10
ADJ US T
P R O C E DUR E
2) ADJ US T T HE DAT A UP /DO W N UNT IL IC 801 P IN 2 V O LT AG E B E C O ME AS S P E C IF IE D B E LO W
[C HE C K ING S P E C ]
2.5 ± 0.5 V DC (C HE C K ING S P E C : 2.50 ± 1.5 V )
HISTORY
S Y MB OL
OF REVISION
21V -R 70MM
P IF -V C O
V 10
S T E P R ANG E
R E V IS E D C O NT E NT .
5 – 11
21V-R70MM
0 - 63