Check Point (Charger Unit); Adjustment Standard (Charger Unit) - Panasonic KX-TCA181RUT Service Manual

Table of Contents

Advertisement

KX-TCD815RUS / KX-TCD815RUT / KX-TCA181RUS / KX-TCA181RUT
8.4.

Check Point (Charger Unit)

Items
(A)
Charging Check
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment is as shown in Adjustment Standard (Charger Unit) (P.34).
8.5.

Adjustment Standard (Charger Unit)

When connecting the Simulator Equipments for checking, please refer to below.
8.5.1.
Flow Solder Side View
DC POWER
+6.0V
(-)
(+)
Note:
(A) is referred to Check Point (Charger Unit) (P.34)
Check
Point
-
1. Connect Charge Contact 12Ω/2W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.10V ± 0.2V.
TP3
TP2
PQUP11348Z
TP1
Procedure
KX-TCD800 SERIES
PQLV30040ZA
PbF
12Ω/2W
TP1
(+)
(-)
Digital
Volt Meter
(A)
34
D2
TP4
R2
R1
TP2
Check or
Replace Parts
D2, R2, R1
A