GE PXRQ15RBL Owner's Manual page 5

Reverse osmosis
Table of Contents

Advertisement

Available languages

Available languages

Specification guidelines.
Contaminant
(1)
Reduction
Arsenic (pentavlent)
Asbestos
Barium
Cadmium
Chromium (Hex.)
Chromium (Tri.)
Copper
Cyst
Lead
Radium 226/228
Selenium
TDS
(2)
Turbidity
Chlorine Taste and Odor
Nominal Particulate Class
III
, ≥ 5 μm to < 15 μm
Operating Specifications
Inlet Pressure
Inlet Temperature
Maximum TDS Level
Maximum Hardness @ 6.9pH
Maximum Chlorine
pH Range
Daily Production Rate
(3)
Efficiency Rating
(4)
Recovery Rating
Notes:
(1) Tested by NSF International per NSF/ANSI Standard 58 or NSF/ANSI Standard 42.
(2) NTU is Nephelometric Turbidity Units
(3) Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate
typical daily usage.
(4) Recovery rating means the percentage of influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is
operated without a storage tank or when the storage tank is bypassed.
Notice: This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 58.
Before purchasing a water treatment unit, it is recommended that you have your water supply tested to determine your actual water treatment
needs. The NSF/ANSI 58 testing were performed under standard testing conditions, actual performance mayvary with local water conditions.
WARNING: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. This system is to be used for
arsenic reduction only on chlorinated water supplies containing detectable residual free chlorine at the system inlet. Water systems using an in-line
chlorinator should provide a one-minute chlorine contact time before the RO system. See Arsenic Fact Sheet for additional details.
This reverse osmosis system contains a carbon pre-filter to help protect the reverse osmosis membrane from deterioration that is induced by
chlorine in the supply water. This reverse osmosis system contains replaceable treatment components critical to the efficiency of the system.
Replacement of the membrane component should be with one of identical specifications, as defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance. The product water should be tested periodically to verify that the system is performing
satisfactorily. Consult the owner's manual for further information on installation, operating instructions, component replacement, and product
warranty.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to
pentavalent arsenic. Please see the Arsenic Facts section of Performance Data Sheet for further information.
Estimated Replacement Costs
FQROPF – Pre- and Post-Filters carbon elements: $34.99 - $39.99
FQROMF – Reverse Osmosis Membrane: $69.99 - $79.99
Rev 4 P/N 101051 0310
System tested and certified by NSF International against NSF/ANSI Standard 42 and against NSF/ANSI Standard 58
for the reduction of substances as listed below according to Standard 42 and 58.
Contaminant Reduction Determined by NSF testing
NSF specified Challenge
Average Influent
Concentration
0.051 mg/L
0.050 mg/L ± 10%
7
8
10
to 10
fibers/L;
fibers greater than 10μm
180 fibers/L
10 mg/L
10 mg/L ± 10%
0.030 mg/L
0.03 mg/L ± 10%
0.3 mg/L ± 10% (added as
0.31 mg/L
hexavalent)
0.33 mg/L
0.3 mg/L ± 10% (added as triavalent)
3.2mg/L
3.0 mg/L + 10%
73,000 cysts/L
Minimum 50,000 cysts/L
0.15 mg/L
0.15 mg/L + 10%
25 pCi/L
25 pCi/L ± 10%
0.10 mg/L ± 10% (added as ½
0.1 mg/L
selenite and ½ selenate)
760 mg/L
750 mg/L + 40 mg/L
138 NTU
11 ± 1 NTU
2.1 mg/L
2.0 mg/L ± 10%
119,333 pts/mL
At least 10,000 particles/mL
2
40-120 psig (2.8-7.0 kg/cm
40-100 F° (5-38° C)
2000 mg/L
10 grains per gal. (171 mg/L)
2.0 mg/L
4 – 10
8.46 GPD (32.0 L/day)
9.05%
19.84%
Performance Data Sheet Profile™ Reverse Osmosis System
Models: PXRQ15FBL, PXRQ15RBL, PNRQ15FBL, and PNRQ15RBL
General Electric Company
.
Average Product
Water
Avg %
Concentration
Reduction
98.0%
0.001 mg/L
99.9
< 1 fiber/L
96.5%
0.341 mg/L
97.6%
0.0007 mg/L
97.5%
0.008 mg/l
96.5%
0.01 mg/l
97.5%
0.008 mg/L
99.99%
5 cyst/L
97.6%
0.003 mg/L
80.0%
5 pCi/L
98.0%
0.002 mg/L
91.6%
64 mg/L
99.9%
0.13 NTU
96.1%
0.08 mg/L
99.2%
948 pts/mL
)
For replacement parts, call toll-free 800.626.2002 (U.S),
800.663.6060 (Canada-English),
800.361.3869 (Canada-French).
Appliance Park
Louisville, KY 40225
Max
Permissible
Product Water
NSF Reduction
Concentration
Requirements
0.010 mg/L
N/A
NA
99%
2.00 mg/L
N/A
0.005 mg/L
N/A
0.1 mg/L
N/A
0.1 mg/L
N/A
1.3 mg/L
N/A
N/A
≥99.95%
0.010 mg/L
N/A
5 pCi/L
N/A
0.05 mg/L
N/A
187 mg/L
N/A
0.5 NTU
N/A
N/A
≥ 50%
N/A
≥85%
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system as specified in
NSF/ANSI Standard 58.
GEAppliances.com
NSF Test
Report
J-00082158
J-00077915
J-00077916
J-00082186
J-00077916
J-00077916
J-00077913
J-00077914
J-00082186
J-00077916
J-00077911
J-00077940
J-00077914
J-00076398
J-00082586
P/N 101051 0310
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pnrq15rbl

Table of Contents