7.9.
Remove the SS2-Board
1. Disconnect the connector (SS02) and disconnect the flex-
ible cable (SS52).
2. Remove the screws (×2
7.10. Remove the SS3-Board
1. Disconnect the connector (SS03) and disconnect the flex-
ible cable (SS57).
2. Remove the screws (×2
7.11. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS02 and SS03).
3. Disconnect the connectors (SS11, SS12 and SS23).
4. Remove a short-jumper connector SS34 and re-use for
new SS-Board.
5. Disconnect the flexible cables (SS54 and SS55).
6. Remove the molding prop (×1
7. Remove the screws (×5
) and remove the SS2-Board.
) and remove the SS3-Board.
).
) and remove the SS-Board.
7.12. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws (×5
each) and remove the Stand brackets (L, R).
20