Hitachi ED-A110A1DN Service Manual page 21

Multimedia lcd projector
Table of Contents

Advertisement

Time in not correctly displayed.
DATE
AND TIME is
NO
displayed as 2000/1/1 0:00
in INFORMATION on
NETWORK
menu.
YES
NO
Was the time set before?
YES
YES
Is internal clock battery
old ?
NO
Is voltage
input at pin 1 of
NO
EE02 on PWB assembly
MAIN when power switch
was turned
off.
YES
2.5V or more
PWB assembly
MAIN
CP-A100 / ED-A100 / ED-A110 (A1DN)
Set the time in
DATE AND TIME on
NETWORK menu.
Use new battery.
(see 6.4)
• PWB assembly BATTERY
• Cables (CNBAT)
• PWB assembly MAIN
21
Is TIME
NO
DIFFERENCE on
INFORMATION correct ?
YES
Is the
NO
time adjusted by
Daylight Savings Time ?
YES
PWB assembly
MAIN
Set the time.
Configure the Daylight
Saving Time in web
setting.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ed-a110Ed-a100a1dnEd-a100Cp-a100a1dnCp-a100

Table of Contents