SERVICE
ADJUSTMENT ITEM
NUMBER
EX1
FAO VOLUME
EX2
CC-POSITION
EX3
INT
EX4
A-ATT
OP1
OPTION1
OP2
OPTION2
M01
INPUT LEVEL
M02
MTS VCO
M03
FILTER
M04
WIDEBAND
M05
SPECTRAL
P01
CONTRAST-PIP
P02
TINT-PIP
P03
COLOR-SAT-PIP
P04
Y-OFFSET-PIP
P05
HXA-PIP
P06
HADJ-PIP
P07
FREE RUN-PIP
P08
TINT-PIP-INPUT
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102.
PART REPLACED
NECESSARY
IC2001
IC201
IC2102
CRT
IC3001
DATA
INITIAL VALUE
24
0-50(00h-32h)
21
0-127(00h-7Fh)
7A
0-255(00h-FFh)
5A
0-127
BA
0-255(00h-FFh)
01
0-7(00h-07h)
09
0-15(00h-0Fh)
24
0-63(00h-3Fh)
1F
0-63(00h-3Fh)
18
0-63(00h-3Fh)
10
0-63(00h-3Fh)
32
0-127(00h-7Fh)
29
0-63(00h-3Fh)
32
0-127(00h-7Fh)
09
0-31(00h-1Fh)
0A
0-255(00h-FFh)
00
0-15(00h-0Fh)
0B
0-15(00h-0Fh)
24
0-63(00h-3Fh)
Table - A
ADJUSTMENT
UNNECESSARY
X
X
X
X
X
Table - B
ADJUSTMENT CONTENTS
RANGE
Must be set to "24"
Must be set to "7A"
Must be set to "B0"
Must be set to "31"
Must be set to "09"
Must be set to "29"
Must be set to "09"
Must be set to "0A"
Must be set to "00"
Must be set to "0B"
Must be set to "24"
NOTES
Data is stored in IC2102.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
above initial values into IC2102. Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M05).
8