Cleaning the pump
The pump should be inspected if
• the machine does not empty and/or
• the machine makes an unusual noise
Proceed as follows:
• Disconnect the appliance.
• If necessary wait until the water has
• Open the pump door.
• Place a containfer close to the pump
• Pull out the emergency emptying
• When no more water comes out,
Downloaded From WashingMachine-Manual.com Manuals
30/08/2006
12:04
P0038
spin
during draining due to objects such as
safety pins, coins etc. blocking the
pump.
cooled down.
P1114
to collect any spillage.
hose, place it in the container and
remove its cap.
unscrew the pump cover and remove
it. Always keep a rag nearby to dry up
spillage of water when removing the
cover.
Pagina
27
care and cleaning electrolux 27
P1115
• Remove any objects from the pump
impeller by rotating it.
• Put the cap back on the emergency
emptying hose and place the latter
back in its seat.
P1117
• Screw the pump cover fully in.
• Close the pump door.
Warning!
When the appliance is in use and
depending on the programme selected
there can be hot water in the pump.