Temperature Rise Table & Graph - Maxwell MSxxxC2T series Installation And Instruction Manual

Tankless electric water heater
Table of Contents

Advertisement

o
Temperature Rise
Model
MS120C2T
Power
(kw)
12
Water
Flow(GPM)
0,5
164
1,0
82
1,5
55
2,0
41
2,5
33
3,0
27
3,5
23
4,0
20
4,5
18
5,0
16
5,5
15
6,0
14
6,5
13
7,0
12
Temperature Rise
o
F
Temp Rise
1 2 3 4 5 6
120
110
100
90
80
70
60
50
40
30
20
10
0
0,5
1,0
1,5
Based upon DOE formula for calculating flow at rise
F
MS150C2T
15
205
102
68
51
41
34
29
26
23
20
19
17
16
15
o
F @ 240V vs. Flow Rate (GPM)
2,0
2,5
3,0
3,5
4,0
MS180C2T
MS210C2T
18
21
246
287
123
143
82
96
61
72
49
57
41
48
35
41
31
36
27
32
25
29
22
26
20
24
19
22
18
20
4,5
5,0
5,5
6,0
10
Table 2
MS240C2T
MS270C2T
24
27
328
369
164
184
109
123
82
92
66
74
55
61
47
53
41
46
36
41
33
37
30
34
27
31
25
28
23
26
1
MS120C2T
2
MS150C2T
3
MS180C2T
4
MS210C2T
5
MS240C2T
6
MS270C2T
Flow Rate
GPM
6,5
7,0
kW rating x 6.83
Flow Rate (gpm) =
Temp rise (ºF)
Diagram 1