Heater Sizing Guide - Maxwell MSxxxC2T series Installation And Instruction Manual

Tankless electric water heater
Table of Contents

Advertisement

10.
AFTER TIGHTENING BOTH FITTINGS AT THE WATER HEATER, PRIOR TO TURNING ON THE
POWER OF THE WATER HEATER, OPEN SEVERAL HOT WATER FAUCETS AND ALLOW WATER
TO RUN THROUGH THE WATER HEATER FOR A MINIMUM OF 3 MINUTES. This process purges all
air from the water lines and the heater.
Fig 9
Connect the cable to the terminal blocks, please notice the guidance logo below the terminal blocks.
The unit will be connected to circuit breakers as per table 1
Average Water Consumpion

Heater Sizing Guide

Inlet Water
77º F
Temp.
Model Nº
MS120C2T_U
2.9 gpm
MS150C2T_U
3.8 gpm
MS180C2T_U
4.3 gpm
MS210C2T_U
5.4 gpm
MS240C2T_U
6.0 gpm
MS270C2T_U
6.8 gpm
Shower (1.5 gpm) ― Sink Faucet (1.0 gpm) - All data above are based on water leaving temperature 105º F (40º C). 1.5 gpm showerhead flow rate;
1.0 gpm sink faucet flow rate, and adequate water pressure @ 60 psi. Actual performance may be altered by variations from these parameters.
For voltages less than 240 V the heating capacities will vary and it would be necessary to consider a higher capacity model.
Application
Typical Shower
Typical Bath Tub Faucet
Bathroom Vanity Sink Faucet
Kitchen Sink Faucet
Clothes Washer
Summer
72º F
67º F
62º F
2.6 gpm
2.4 gpm
2.3 gpm
3.4 gpm
2.9 gpm
2.8 gpm
3.9 gpm
3.4 gpm
3.3 gpm
4.8 gpm
4.1 gpm
3.8 gpm
5.2 gpm
4.5 gpm
3.8 gpm
5.7 gpm
5.1 gpm
4.4 gpm
Flow Rate in
GPM at 60 PSI
1.5 to 2.0 GPM
2.0 to 3.0 GPM
0.5 to 1.5 GPM
1.0 to 2.2 GPM
1.5 to 3.0 GPM
57º F
52º F
2.0 gpm
1.8 gpm
2.6 gpm
2.2 gpm
2.9 gpm
2.8 gpm
3.5 gpm
3.0 gpm
3.7 gpm
3.2 gpm
3.9 gpm
3.6 gpm
9
Table 1
Winter
47º F
42º F
37º F
1.5 gpm
1.3 gpm
1.2 gpm
1.9 gpm
1.8 gpm
1.4 gpm
2.6 gpm
2.3 gpm
2.0 gpm
2.8gpm
2.5 gpm
2.4 gpm
3.0 gpm
2.7 gpm
2.5 gpm
3.3 gpm
3.0 gpm
2.7 gpm