PCB v1.0.2
Jumpers
There are six jumpers on the back, labeled 3, 4, 5, 6, 7, and 8. Each can be set with a jumper plug, or an optional break-out
panel with switches. The jumper positions vary among PCB versions. See the above photos to identify the location of
jumpers on your PCB (the PCB version is written in white letters near the /8 Jack).
Jumpers 3 and 4: Max Divide-by Range
Div
Range
Total Rotatable
Jumpers
Divide-by range
3
4
in
in
1 to 8
in
no
1 to 16
no
in
1 to 32
no
no
1 to 64
Jumper 7: Up-beat/Down-beat counting
Up/Down
in
Down-beat counting
no
Up-beat counting
Divide-by amount on
jacks with no voltage
applied to CV Rotate
Jack (tables 2-5)
1 to 8
9 to 16
17 to 24
33 to 40
Mode
PCB v1.0.1
Jumpers 5 and 6: Auto-reset
Auto-
Reset
with Divide-by range of...
Jumpers
5
6
1 to 8 1 to 16 1 to 32 1 to 64
in
in
32
64
in
no
16
32
no
in
24
48
no
no
none
none
Jumper 8: Gate/Trigger mode
Gate/Trigger
in
Gate mode
no
Trigger mode
Auto-reset
128
256
64
128
96
192
none
none
Mode

Advertisement