Maintenance Schedule
Item
Check Engine Oil
Replace Engine Oil
Check Air Filter
Clean Air Filter
Spark Plug
Carburettor Float Chamber
6. TROUbLESHOOTING
Problem
Cause
Engine will not start
Insufficient fuel
Engine switch in "OFF" position Switch to "ON"
Engine oil is low
Spark plug fouled
Incorrect starting technique
No power generated Circuit breaker in OFF position
Incorrect voltage selected
7. DECLARATION OF CONFORMITY
WARNING! The warnings, cautions and instructions discussed in this manual cannot cover all possible conditions and situations that may
occur. It must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the
operator.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Daily Check
20hrs or first month
 Check
 Replace
 Check
Cover
Screws
Fig.7
Remedy
Check and refill fuel tank
Check and top up oil
Clean or replace spark plug
Read section 3.4.5 for correct technique
Reset to ON
Set switch to correct voltage (excluding GG1100)
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
50hrs or every 3 months
100hrs or every 6 months
 Clean
Foam
Element
Fig.8
01284 757500
01284 703534
300hrs or yearly
 Replace
 Clean
 Clean
Fig.10
www.sealey.co.uk
Web
sales@sealey.co.uk
email
GG1100, GG2800, GG3800, GG7500
 Replace
Float
Chamber
Fig.9
0.7 to 0.8mm