Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment.
Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
9
Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
9
Unauthorised parts may be dangerous and will invalidate the warranty.
This generator is designed and manufactured for specific applications. DO NOT attempt to modify the unit or use it for any application for
9
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey stockist.
WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for
connection at any one time, the total must not exceed rated wattage of generator (see specifications).
WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.
WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the
frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. This
connection should only be attempted by a qualified electrician, after first having consulted your local stockist.
DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the
generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of the
exhaust and/or cooling ventilation, will eliminate the danger.
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the
commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a
back-feed of electrical energy.
DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires,
terminals etc. Never allow any unqualified person to operate or service the generator.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the vicinity
while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of fuels.
WARNING! Risk of burns. DO NOT touch the exhaust system or the drive unit.
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow cool down time.
Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
9
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
DO NOT tip or change the generator's position whilst it is operating.
8
Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
9
Keep non-essential persons and children away from the working area.
9
WARNING! Never start or stop the generator while electrical loads are connected. Start the engine, let it stabilise, then connect the
electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.
WARNING! DO NOT use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in electric
shock.
DO NOT use the generator for any purpose other than that for which it is designed.
8
DO NOT operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
8
© Jack Sealey Limited
3100W 230V GENERATOR 7HP - 4-STROKE ENGINE
G3101.V2
MODEL NO:
Refer to instruction
manual
Hot parts.
Keep your distance
Switch off the engine
Before refuelling
Never operate in
Non-ventilated rooms
Original Language Version
G3101.V2 Issue1
20/01/23

Advertisement

loading

Summary of Contents for Sealey G3101.V2

  • Page 1 This generator is designed and manufactured for specific applications. DO NOT attempt to modify the unit or use it for any application for which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey stockist.
  • Page 2: Specification

    Long running with up to 11 hours on a full tank. Fitted with two 230V 13A sockets. Powerful and reliable generator. Smooth running unit fitted with anti-vibration engine mounts. Features low oil warning light, overload protection and fuel gauge. 3. SPECIFICATION Model no: ............G3101.V2 Continuous Power Rating:........2600W Current Rating: ............11.3A Dimensions (W x D x H): ....595 x 435 x 435mm Fuel ............
  • Page 3 4.3. FOOT SEE FIG.5 4.3.1. Bolt feet, one each side, to frame at the opposite end from the axle (16). 4.4. HANDLE SEE FIGS 7 & 8 4.4.1. Bolt brackets (17) to frame. Bolt handle (18) to brackets, see fig.8. © Jack Sealey Limited G3101.V2 Issue1 20/01/23 Original Language Version...
  • Page 4: Electrical Safety

    6.5.5. Push the choke lever, see fig.2.11 back again after the engine has started. CONNECTING EQUIPMENT TO THE GENERATOR ‰ 6.5.6. Connect the equipment you want to use to the 230V sockets, see fig.1.3. Important: These sockets may be loaded continuously (S1) with 2000W and temporarily (S2) for a maximum of 2 minutes with © Jack Sealey Limited Original Language Version G3101.V2 Issue1 20/01/23...
  • Page 5: Maintenance

    WARNING! Switch off the motor and pull the spark plug boot from the spark plug before doing any cleaning and maintenance work ‰ on the equipment. Important: Switch off the machine immediately and contact your Sealey stockist: In the event of unusual vibrations or noise or if the engine appears to be overloaded or misfires.