Troubleshooting; Equipment List - Sony Ericsson C702 Troubleshooting Manual

Table of Contents

Advertisement

C702 Equipment List
Note: More additional information about the equipment used for TRS can be found in Repair
Tools Catalogue on CSPN or on the following location: CSPN – Repair Instructions – Electrical –
C702 – Equipment List.
TRS Fixture Kit
Location: CSPN-Repair Instructions-Electrical-C702-Equipment List
Dummy Battery
Location: CSPN-Repair Instructions-Electrical-C702-Equipment List
Part number: NTZ 112 533
Note! The resistance between GND and BDATA should be approximately 120K Ohm.
Instruments
Power Supply Channel 1 VBATT
Agilent 6632B or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
Instrument Settings:
Voltage: 3.8 Volt
Limiter: 2A
Note: During the calibration the accurate voltage from the VBATT must be within ±0.015 V. If
this is not fulfilled it will result in a faulty calibration. (For more information about
recommended power supply units, see the Repair Tool Catalogue on CSPN under the Mechanical
level. The Power Supply Channel 1 VBATT must allow reverse current.
Note: Maximal cable length between the Power Supply Channel 1 VBATT and the dummy
battery must be maximum 1m. The cable must have a capacity for at least 16A.
Note: It is very important to follow instrument settings instructions when performing the
Battery Calibration Test.

TROUBLESHOOTING

Equip ment List
Power Supply Channel 2 DCIO/SEPI
Agilent 6632B or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
Instrument Settings:
Voltage: 5.0 Volt
Limiter: 2A
Note: It is very important to follow instrument setting instructions when performing the
Current Calibration Test.
Oscilloscope
Tektronix TDS 2012 or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
Digital Multimeter (DMM)
Fluke 83 or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
The 0, 64 mm Test Probes is recommended by Sony Ericsson when DMM is in use see picture 1.
Picture 1
Spectrum Analyzer
HP 8595E or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
RF probe
HP 85024A or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
Mobile Phone Tester
Yokogawa VC230 or similar
Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue
FM Signal Generator
Agilent E4433B or similar
Location: -
RF Adaptor
Adaptor 33 N-BNC-50-1
Adaptor to Signal Generator RF Output
See Picture 2
Location: -
SEMC Troubleshooting Manual
C702
1221-7857 rev. 1
3