    Audio Zone Amplifier 100W Operation Manual 500217 © MuxLab Inc. 2016 94-000839-A / SE-000839-A...
  • Page 2  Unpack the equipment carefully and save the original box and packing material for possible future shipment.  Please read this user manual carefully before using this product. © MuxLab Inc. 2016...
  • Page 3: Table Of Contents

    Audio Zone Amplifier 100W Operation Manual Contents Introduction ....................... 4 1.1. Introduction to the 500217 ................4 1.2. Features ......................4 1.3. Package Content ................... 5 Specification ......................6 Panel Description ...................... 7 3.1. Front Panel ....................7 3.2. Rear Panel ..................... 8 System Connection ....................
  • Page 4: Introduction

    Supports 2x50 Watts for 2CH audio @ 8Ω.  Supports 1x100 Watts for mono bridge mode function @ 4Ω. This is also appropriate to support 70V speaker systems when connected to a MuxLab 70V transformer such as the 500755-70V. ...
  • Page 5: Package Content

    Two (2) Detachable Mounting Ears  Four (4) Screws  Four (4) Plastic Feet  One (1) User Manual Please verify that the product and the accessories are all included; if not, please contact your dealer. © MuxLab Inc. 2016...
  • Page 6: Specification

    Audio Zone Amplifier 100W Operation Manual Specification Environment Analog Audio Devices Audio System, Line Output, Microphone, Speaker Compatibility Compatible with MuxLab Analog Audio products Transmission Transparent to the user Frequency Response 20Hz to 20KHz CMMR >75dB @ 20Hz-20KHz 80dB at maximum output >10KΩ...
  • Page 7: Panel Description

    Operation Format: “INPUT SEL” + “CONTROL” + “Volume Knob” Example: To adjust bass audio of input 3, select input 3 -> choose bass -> adjust the volume (level) knob. © MuxLab Inc. 2016...
  • Page 8: Rear Panel

    33VDC, 4A power adapter Input Jack DC 33V Connect for grounding purposes Note: When connecting or disconnecting speakers, make sure to disconnect the power from the Audio Zone Amplifier 100W first to avoid electric shock or damage. © MuxLab Inc. 2016...
  • Page 9: System Connection

    Step 5 (Optional) Connect a control device (e.g. a PC) to an Ethernet LAN and the amplifier TCP/IP port to the same LAN to enable IP control. Step 6 Plug 33VDC power adaptor to the power port of the amplifier. © MuxLab Inc. 2016...
  • Page 10: Audio Output Connection

    Connect the amplifier and speaker(s) as shown in the figure below: Figure 4- 2 Mono Output Connection Note: In mono mode the user can also connect a MuxLab 70V transformer such as the 500755-70V to support 70V daisy-chained speaker systems. This is useful for longer speaker runs in a distributed speaker environment.
  • Page 11: Loop (Cascade) Connection

    The Audio Zone Amplifier 100W is well suited for applications such as classrooms, small meeting rooms, lecture halls, bars/pubs, etc. Also in MONO (bridged) mode with an attached MuxLab 70V transformer, 70V speaker systems may be utilized supporting longer distances and speaker daisy chaining for larger distributed applications.
  • Page 12: System Control

     LINE: Line volume ranges from 0 to 60, where each additional volume bar increases the volume level by 6, while a decrease in one volume bar decreases the volume level by 6. © MuxLab Inc. 2016...
  • Page 13: Ir Control

    Connect an IR receiver (5V, without carrier) to the IR Sensor port on the rear panel. This allows the user to control the amplifier by the included IR remote (see below): Input Selection Mute Unmute Volume Control Including LINE, BASS and TREBLE volume adjustment Figure 4- 2 IR Remote © MuxLab Inc. 2016...
  • Page 14: Rs232 Control

    Amplifier 100W. 5.3.1 Basic RS232 Settings You can use a terminal software to control the 500217. Please set the parameters of the COM Port (baud rate, data bit, stop bit and the parity bit) to 9600, 8, 1, none (respectively).
  • Page 15: Rs232 Communication Commands

    Volume of LINE: 54 7[x][x]% Preset line volume, [xx] can be 00~60, 61 Volume of LINE: 50 degrees in total. 8[x][x]% Preset the bass level, [xx] can be 00~10, Bass of LINE: 7 11 degrees in total. © MuxLab Inc. 2016...
  • Page 16: Ethernet Control

    PC network segment to the same network segment of the Audio Zone Amplifier. Same network segment as the Audio Zone Amplifier  Controlled by any PC in the LAN Before connecting the Audio Zone Amplifier to the same network as the PC to be used © MuxLab Inc. 2016...
  • Page 17: Control Via Tcp/Ip Communication Software

    1) Connect a computer and the Audio Zone Amplifier to the same network. Open the TCPUDP software (or any other TCP/IP communication software) and create a connection, enter the IP address and port of the Audio Zone Amplifier (the default IP is: 192.168.0.178, port:4001): © MuxLab Inc. 2016...
  • Page 18: Control Via Web Based Gui

    This GUI allows users to interact with the Audio Zone Amplifier through graphical icons and visual indicators. Type 192.168.0.178 (default IP, changeable via GUI) in your browser, which will bring up the log-in screen, as shown below: © MuxLab Inc. 2016...
  • Page 19 Figure 5- 4 Network Control Web Interface With-in this interface, the user can:  Select the input source  Mute/ Unmute the output  Control the levels for LINE/ BASS/ TREBLE by dragging the dot up or down to © MuxLab Inc. 2016...
  • Page 20: Port Management

    Clear the cache of the browser beforehand to ensure reliable GUI operation. 5.4.4 Port Management Enter the Audio Zone Amplifier 100W IP Address 192.168.0.178:100 (Default, changeable via GUI) into a web browser. Enter the correct username and password to log in to the webserver interface: © MuxLab Inc. 2016...
  • Page 21: Panel Drawing

    DC 33V 13.50 mm Ω 2x50Watt@8 Analog and Digital Audio Intput Control By Rs232, IR, Panel Button Ω Bridge Connection,1x100Watt@8 Adjust Bass, Treble and Volume via A Knob Audio Amplifier 2x50W LINE BASS INPUT SEL CONTROL VOLUME © MuxLab Inc. 2016...
  • Page 22: Troubleshooting & Maintenance

    Audio Zone Amplifier 100W Operation Manual Troubleshooting & Maintenance The following table describes some of the symptoms, probable causes and possible solutions in respect to the installation of the 500217 Audio Zone Amplifier 100W. Problem Possible Cause Solution Loose or broken connection at Reconnect the devices.
  • Page 23 Wrong input selected on the 1 Audio Zone Amplifier Audio Zone Amplifier 100W. 100W. If you still cannot diagnose the problem, please call MuxLab Customer Technical Support at 877-689-5228 (toll-free in North America) or (+1) 514-905-0588 (International). © MuxLab Inc. 2016...
  • Page 24: Regulatory Compliance

    All brand names and product names used in this document are trademarks, or registered trademarks of their respective holders. 8495 Dalton Road, Mount Royal, Quebec, Canada. H4T 1V5 Tel: (514) 905-0588 Fax: (514) 905-0589 Toll Free (North America): (877) 689-5228 E-mail: videoease@muxlab.com URL: www.muxlab.com © MuxLab Inc. 2016...