Electrical Specifications - Daikin EHBX04C3V Technical Data Manual

Altherma low temperature split
Hide thumbs Also See for EHBX04C3V:
Table of Contents

Advertisement

2
Specifications

2-2 Electrical Specifications

Power supply
Voltage range
1
Wiring connections-
Quantity
Communication cable
Remark
2
Wiring connections-
Quantity
Electric meter
Wiring connections-
Quantity
Preferential kWh rate
power supply
Wiring connections-
Quantity
Domestic hot water
Remark
pump
Wiring connections-
Quantity
For power supply
Remark
connection to optional
*KHW*
Wiring connections-
Quantity
For connection to
Remark
optional *KHW* model
+ Q2L
Wiring connections-
Quantity
For connection with
Remark
R5T
Wiring connections-
Quantity
For connection with
Remark
R6T
Wiring connections-
Remark
For connection with
A3P
Wiring connections-
Quantity
For connection with
Remark
M2S
Wiring connections-
Quantity
For connection with
Remark
M3S
Wiring connections-
Quantity
For connection with
Remark
bottom plate heater
Wiring connections-
Quantity
For connection with
Remark
user interface
Wiring connections-
Quantity
For connection with
Remark
optional FWXV*
(demand input and
output)
Notes
Notes
(1) With option kit *KHBDP installed: Height = XXX mm
(2) DB/WB 7ºC/6ºC - LWC 35ºC (DT=5ºC)
(3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
(4) The sound pressure level mentioned is maximum possible value inside operation range of unit
(5) 15ºC-25ºC: BUH only, no heat pump operation = during commisioning
(6) Including piping + PHE + back-up heater; excluding expansion vessel
(7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE
(8) See separate drawing for operation range
(9) \> 50ºC BSH only, no heatpump operation
(10) BUH 3V/9W can only operate at flow \> 12/15 l/min
(11) Refer to operation range for detail for differences between *RHQ* and *RLQ* models
(12) PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
4
• Daikin Altherma low temperature split • EHBX-C
Min.
%
Max.
%
Select diameter and type according to national and local regulations / For more details of the voltage
Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
Voltage: 230V / Max.current: 100mA / Min. 0.75mm² / Select diameter & type according to national &
Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
• Heating • Daikin Altherma low temperature split
EHBX04C3V
EHBX08C3V
Minimum 0.75 mm² (2A inrush, 1A continuous)
13A (Select diameter and type according to national and local regulations)
range and current, refer to installation manual
Wire included in option *KHW*
Wire included in option *KHW*
Minimum 0.75 mm²
Select diameter and type according to national and local regulations
0,75 mm² till 1,25 mm² (max length 500m)
100 mA, minimum 0.75 mm²
PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
EHBX08C9W
EHBX16C3V
10
10
3
2.5 mm²
2
Power: 2
2
3G
5G
2
/ Min. 0.75mm²
2
local regulations
3
/ Min. 0.75mm²
2
2
4
EHBX16C9W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehbx16c3vEhbx08c3vEhbx16c9wEhbx08c9w