GW-482S INSTALL ATION GUID E Revision History Rev ision Date Description October 2005 Created December 2005 Added support f or GW-482S-LV-2-G and GW-482S-LV-4-G MN100143 Rev B...
Page 4
Disconnect the product from the power line before removing the cover. Any adjustment and maintenance of the opened device should be done only while the device is disconnected from its source of power and should only be performed by qualified personnel, authorized by Telco. GROUNDING Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the ground by a standard grounding conductor.
Table of Contents INTRODUCTION......................1 ......................1 OW TO ...................... 2 EFORE NSTALL INSTALLING THE GW-482S.................... 5 ....................5 OUNTING THE ABINET ................. 6 ONNECTING THE ABINET TO THE ROUND ..................7 IBER PTIC ABLE ONNECTION ....................8 OWER ABLE...
This guide provides installation instructions for the GW-482S family of VoIP Gateway systems. The GW-482S is comprised of a VoIP gateway board, a battery backup and an AC/DC adaptor in an outdoor cabinet. Figure 1 shows the main components of the GW-482S system.
2. Familiarize yourself with the equipment and unit (see pictures below). Packing List • GW-482S Cabinet with EdgeGate 482S VoIP Gateway Board. • 110/220 V AC/DC Adaptor + AC power cable (not included with GW-482S-LV-X-G). • T wo wall mounting bars. • Cardboard mounting template.
Page 8
GW-482S INSTALL ATION GUID E Accessories for attaching Flanges and Neoprene Mounting Cardboard and positioning wires gaskets bars mounting template Figure 2: Mounting Bars and Accessories Figure 3: Console Cable MN100143 Rev B...
Page 9
GW-482S INSTALL ATION GUID E Console Grounding The RS-232 cable must be connected to a floating PC, i.e. laptop, to prevent the unit from being permanently damaged. NOTE The console cable is provided for use by serv ice personnel for configuring the EdgeGate 482S VoIP Gateway, as described in the EdgeGate VoIP Gateway H.323, MGCP, SIP User Guide (Document MN100112).
Connect the AC power cable. Install the battery. Mounting the Cabinet The following items are provided for mounting the GW-482S cabinet on a wall: • T wo mounting bars with affixed screws. Figure 5: Cabinet Mounting Bars • A cardboard mounting template (PK000195) with drill-position marks.
Figure 7: Attaching the Cabinet to the Upper Mounting Bar Connecting the Cabinet to the Ground Before making electrical connections to the GW-482S, you must connect the cabinet to a sound and secure ground. The grounding shall be performed in accordance w ith Article 810 of NEC or Section 54 of CEC.
GW-482S INSTALL ATION GUID E Fiber Optic Cable Connection The fiber optic transmitter is a Class 1 Laser product that may endanger your eyes. Do not look directly into the fiber optic cables or transmitter. NOTE Fiber optic connectors, especially fiber edge (Ferula), must be professionally furbished and clean.
3. Roll and fit the cable slack into the cable holders on the cabinet walls. 4. For GW-482S-LV-X connect the BNC connector to the Con 5 connector on the Main Board. Skip sections on “ Connecting the AC Power Cable” and “ Installing the Battery”...
GW-482S INSTALL ATION GUID E Connecting the AC Power Cable Electric power is supplied to the unit through the AC/DC adaptor. Make sure the power cable is inserted through the opening at the bottom of the unit. 1. After inserting the power cable into the unit, take the AC connector (black plug) from the accessories and open it.
GW-482S INSTALL ATION GUID E Installing the Battery Use battery w ith ¼ inch connectors. Use only a UL approv ed battery. Use a 12V, 7.2AH, valve regulated (sealed) lead-acid battery. Keep the battery operating discharge temperature range between -20° to +50° Celsius.
Page 16
GW-482S INSTALL ATION GUID E 3. Place the battery in the battery compartment. Figure 15: Battery in the Battery Compartment The charger board contains a reverse-polarity-protection circuit and an over-current protection fuse. Should a fuse blow out due to an improper or...
GW-482S INSTALL ATION GUID E Connecting Ethernet and Phone Cables Installation Instructions for a Unit Supplied Without a Patch Panel The user must connect the data and voice communication cables to the Port and Phone connectors on the gateway board.
Page 18
Description Eight (8) 10/100BaseT/TX ports with RJ-45 connectors. LAN Ports (For GW-482S-x-F, TX port #8 is not active if FO port is selected). Connect computers to these ports using straight-through cables, or any other 10/100BaseT/TX compatible devices using appropriate cables.
GW-482S INSTALL ATION GUID E Installation Instructions for Unit Supplied With Patch Panel Required Equipment • Type-110 insertion tool • Screwdriver • Recommended cables: For 10/100BaseT X LAN ports connections, use shielded twisted pair 100 Ohm CAT 5, also called STP CAT 5 with a solid wire.
Page 20
4. Use the Type-110 insertion tool to connect the DT MF wires to either side of the blue mark on the P1 and P2 connectors on the Patch Panel. Up to 5 phones can be connected in parallel to each connector. (For GW-482S-4-x you may also connect P3 and P4). See picture below.
Page 21
GW-482S INSTALL ATION GUID E • Insert user cables directly into user’s house. Do not run cables beyond 140 feet outdoors! • Cables may NOT be connected to TNV (Telecommunication Netw ork Voltages). • Do not connect any port or cable from/to the telephone netw ork!
Management or voice activity Management activity Mngt Besides the four status LEDs, the GW-482S includes nine Link/Activity LEDs, under the RJ-45 connectors. SFP Link Activity The SFP Line Activity LED is located on top of the SFP cage. See picture below: •...
GW-482S INSTALL ATION GUID E Link LED Figure 21: SFP Link Activity LED Battery Charger Diagnostics NOTE Not relevant for GW-482S-LV-X-G units. The Battery Charger has three diagnostic LEDs as shown below. Input Power LED Rev ersed Battery Polarity Output Power...
GW-482S INSTALL ATION GUID E Patch Panel Kit Installation Appendix A Required Equipment • Edge Gate Patch Panel Installation kit • Type-110 insertion tool • Recommended cables: For 10/100BaseT X LAN ports connections, use shielded twisted pair 100 Ohm CAT 5, also called STP CAT 5 with a solid wire.
Page 26
GW-482S INSTALL ATION GUID E T ake the supplied RJ45 cables from the plastic bag. Connect one end of an RJ45 cable to the Ethernet Port2 on the Gateway board. Connect the other end to the L2 port on the Patch Panel.
Page 27
GW-482S INSTALL ATION GUID E Phone 2, respectively, on the Gateway board. In case of GW-482S-4, connect RJ11 cables to P3 and P4 and Phone 3 and Phone 4, respectively. RJ-11 Phone RJ-45 LAN connections connections Figure 26: GW-482S LAN and Phone Connections T ie wires together using the white tie strips for easier access in the future.
GW-482S INSTALL ATION GUID E Cable Pinouts Appendix B Table 5: Telephone Interface Pin-to-Signal Mapping Signal not in use 1, 2 Ring not in use 5, 6 Table 6: 10/100BaseT/TX Interface Pin-to-Signal Mapping Signal Rx + (receive positive) Rx - (receive negative)