  • Page 1 LASERMET AA-05-PIR Audio Alert PIR Triggered Recorded Message Playback Device 01572-53-000 Page 1 of 17 Issue 1 22 May 2014...
  • Page 2: Table Of Contents

    AA-05-PIR Audio Alert Instruction Manual AA-05-PIR Audio Alert Instruction Manual Contents Introduction ........................4 Recording a Message ....................5 Wiring ..........................9 Adjusting Volume ......................10 Installation ........................11 Using the AA-05-PIR ....................16 Specifications ......................17 Contact Details ......................17...
  • Page 3: Ce Declaration Of Conformity

    AA-05-PIR Audio Alert Instruction Manual CE Declaration of Conformity Manufacturer: Lasermet Ltd. Lasermet House, 137 Hankinson Road, Bournemouth BH9 1HR U.K. Equipment: AA-05-PIR Audio Alert 01303-00-000 Standard Applicable Directives: Low Voltage Directive 73/23/EEC CE Directive 93/68/EEC EMC Directive 2004/108/EC European Standards to which conformity is declared:...
  • Page 4: Introduction

    However, the devices can be readily used independently from Lasermet Interlock systems. The AA-05-PIR plays back a recorded message up to 40 seconds long (13 seconds default) when it detects motion (e.g. a person walking past) with its integrated PIR sensor.
  • Page 5: Recording A Message

    Recording a Message Generally, the customer can provide Lasermet with digital audio files when ordering an AA-05-PIR and Lasermet will upload the files onto the device for the customer prior to delivery. Lasermet also has an in-house vocalist who can record written messages onto the AA-05-PIR prior to delivery.
  • Page 6 AA-05-PIR Audio Alert Instruction Manual Step 2 – Connect Power Figure 2: Connecting Power Cable Connect the power cable to the power input connector on the outside of the device (Refer to “Wiring” section if in doubt) 01572-53-000 Page 6 of 17...
  • Page 7 Connect the AA-MIC to connector J3 (Record 1) on the circuit board, making sure that Pin 1 on the AA-MIC is aligned with pin one on J3. Ensure power supplied on to the AA-05-PIR, and the power keyswitch is in the “On” position.
  • Page 8 Repeat this process until you are satisfied with the message. To record the second message on the AA-05-PIR, attach the AA-MIC to J12 (Record 2) connector on the circuit board, set the message select keyswitch to the “1”...
  • Page 9: Wiring

    The AA-05-PIR is supplied with an open-ended lead which connects to the power input on the AA-05-PIR. The open ended leads has two cores, the red should be connected to the positive of the power supply and the blue to the negative.
  • Page 10: Adjusting Volume

    AA-05-PIR Audio Alert Instruction Manual Adjusting Volume Figure 6: Volume Adjuster In order to adjust the volume of the playback, a small screwdriver should be used to turn the volume adjuster (pictured above) clockwise to increase volume or counter- clockwise to decrease the volume.
  • Page 11: Installation

    AA-05-PIR Audio Alert Instruction Manual Installation The AA-05-PIR is supplied with a tilting bracket, which is permanently attached to a wall or other fixed vertical surface. The AA-05-PIR itself then attaches to this bracket by means of a padlock. This permits simple and easy removal of the device, whilst still preventing unauthorised removal.
  • Page 12 Using suitable screws for the wall or vertical surface you are mounting the bracket to, screw through whichever of the 8 small holes on the rear of the bracket are most convenient to the installation. Lasermet recommends using the holes as shown in Figure 7.
  • Page 13 The small holes on the sides of the bracket can be used to locate the front half of the bracket at an angle. This allows the AA-05-PIR to be pointed at the location to be monitored by the PIR sensor.
  • Page 14 Mounting the AA-05-PIR Figure 9: Mounting AA-05-PIR Pass the lugs on the rear of the AA-05-PIR through the two holes on the front of the bracket. You will notice that the Velcro dots on the AA-05-PIR meet with the Velcro dots on the bracket.
  • Page 15 AA-05-PIR Audio Alert Instruction Manual Figure 10: Mounted AA-05-PIR The AA-05-PIR is now held securely in place. 01572-53-000 Page 15 of 17 Issue 1 22 May 2014...
  • Page 16: Using The Aa-05-Pir

    Using the AA-05-PIR Once the AA-05-PIR is mounted on the wall and the power supply cabling is attached, the power supply can be turned on. It is suitable for the AA-05-PIR power cable to be attached while the power supply is on.
  • Page 17: Specifications

    Weight: 510g. Operating Voltage: +6 to +24VDC. Power Consumption: 0.48W standby, 3.8W activated. All figures quoted are approximate. Lasermet reserve the right to alter specifications without prior notice. Contact Details For sales and technical support: Lasermet Ltd. Lasermet House, 137 Hankinson Road,...