Safety Check After Servicing - Philips MDV530VR/17 Service Manual

Digital video disc player & video cassette recorder
Table of Contents

Advertisement

Safety Check after Servicing

Examine the area surrounding the repaired location for
damage or deterioration. Observe that screws, parts,
and wires have been returned to their original posi-
tions. Afterwards, do the following tests and confirm
the specified values to verify compliance with safety
standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)
Table 1 : Ratings for selected area
AC Line Voltage
Clearance Distance (d) (d')
120 V
Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current
between B (earth ground, power cord plug prongs)
and externally exposed accessible parts (RF termi-
nals, antenna terminals, video and audio input and
output terminals, microphone jacks, earphone jacks,
etc.) is lower than or equal to the specified value in the
table below.
Measuring Method (Power ON) :
Insert load Z between B (earth ground, power cord
plug prongs) and exposed accessible parts. Use an
AC voltmeter to measure across the terminals of load
Z. See Fig. 2 and the following table.
Table 2: Leakage current ratings for selected areas
AC Line Voltage
120 V
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
3.2mm (0.126 inches)
Load Z
0.15µF CAP. & 1.5kΩ RES.
Connected in parallel
Chassis or Secondary Conductor
Primary Circuit Terminals
d'
Exposed Accessible Part
Z
1.5k
0.15 F
Earth Ground
B
Power Cord Plug Prongs
Leakage Current (i)
i≤0.5mA Peak
1-3-2
d
Fig. 1
AC Voltmeter
(High Impedance)
Fig. 2
Earth Ground (B) to:
Exposed accessible parts
DVD_SFN1

Advertisement

Table of Contents
loading

Table of Contents