Ambient Temperature Range
Liquid Temperature Range
Ingress Protection Rating
Pre-Start Timer
Start-up Timer
Pressure Timer (Mode 4 Only)
Run-on Timer
Pressure Dip Timer (Mode 4 Only)
Delayed Restarting (Modes 1 to 3 Only)
Cyclic Running
Anti Cycling (Modes 1 to 3 Only)
Run Dry Auto Restart (User Settable to
Single or Repeated Attempts)
Maximum Operating Pressure Static
or Dynamic
Minimum Burst Pressure, all Models
Starting Pressure Range
Stopping Pressure Range
Minimum Pressure Differential On to Off
Recommended pipe size
NOTE: The F60 must NOT be used in hot water applications >60°C. The controller
is rated to withstand water pressure to 20 Bars (290 psi) and must not be used in
applications where the static or dynamic pressure exceeds this rating.
Operating Range
1ºC to 50ºC
1ºC to 60ºC See note below
IP67
Adjustable from 1second to 4 minutes
in 1 second increments.
Adjustable from 1second to 4 minutes
in 1 second increments.
Adjustable from 1second to 15 minutes
in 1 second increments.
Adjustable from 1 second to 15 minutes
in 1 second increments.
Adjustable from 1 second to 4 minutes
in increments of 1 second
Adjustable from 1 minute to 99 Hours
59 minutes in 1 minute increments.
Running and stopping times both
adjustable from 1 minute to 99 Hours
59 minutes in 1 minute increments.
Adjustable from 1 motor start per hour
to 1800 starts per hour.
Adjustable from 1 minute to 99 Hours 59
minutes in 1 minute increments.
20 Bars 290 psi. See note below
> 30 Bars 435 psi
0 to 2000 kPa or 0 to 290 psi in steps
of 1 kPa or 1 psi.
0 to 2000 kPa or 0 to 290 psi in steps
of 1 kPa or 1 psi.
1kPa or 1 psi. Practical limit is nominally
10kPa or 1.5 psi.
25mm 1" or larger. (There is no upper limit).