DIGITAL CLAMP METER AX-7250 INSTRUCTION MANUAL...
Page 2
Symbols on the instrument and in the instruction manual: Warning! Warns of potenitial danger, comply with theiInstruction manual. Caution! Dangerous voltage. Danger of electrical Shock. Continuous double or reinforced insulation complies to IEC 61140, Class II Symbol for the marking of electrical and electronic equipment (WEEE Directive 2002/96/EC).
Page 3
Safety measures The instrument has left our factory in a safe and perfect condition. To maintain this condition, the user must pay attention to the safety references contained in this instruction manual. Warning! His instruction manual contains both information and warnings that are necessary for the safe operation and maintenance of the instrument.
Page 4
Appropriate Usage The instrument must only be used under the conditions and for the purposes for which it has been constructed. Particular attention should be paid to the safety instructions, the technical specifications relating to environmental conditions and the use of the instrument in dry surroundings.
Page 5
and prevents a slipping of the hand inadvertently to the front, unsecured area of the clamp-on ammeter. Do not apply around or remove from HAZARDOUS LIVE conductors. Prior to usage and measurement check that the instrument is In perfect working order, for example At a known current source.
Page 6
Caution! Do not apply around or remove from HAZARDOUS LIVE conductors. Warning! Only use the instrument in circuits fused with max. 16A Warning! Before switching to a New function, the probes must always be removed from the UUT (Unit Under Test) DC Voltage measurement 1) Select measurement range “...
Page 7
The polarity at the red lead (socket) is “+” Data-Hold function If the display is not visible during measurement, press the “DH” button (9) to retain the display. The clamp can then be removed from the conductor and the stored value read. Min/Max Functions Facility to switch between 4 measurement modes pressing the MIN/MAX key (7), in accordance with the following table:...
Page 8
5) Replace the old battery with the new one by respecting the correct polarity! For the battery type, please refer to the technical data section. 6) Carefully close the casing. 7) Insert the screws and ensure they are tightened. Warning! If the instrument is likely to remain unused for a long period of time the batteries must be removed.
Page 9
AC Current 50/60 Hz Range Resolution Tolerance Over Voltage Pr. 40 A 0,01 A ±(2% rdg.+10 digit 600V 400A 0,1 A AC Current 70-400 Hz Range Resolution Tolerance Over Voltage Pr. 40 A 0,01 A ±(3% rdg. +10 digit 600 V 400 A 0,01 DC Voltage...
Page 10
12 months’ guarantee The instrument are subject to stringent quality controls. If, in the course of normal daily use a fault should occur, we provide 12 months’ guarantee (only valid with invoice). Faults in manufacture and materials will be rectified by us free of charge, provided the instrument has not been tampered with, and is returned to us unopened.