Cool - Panasonic WH-UD09HE5-1 Operating Instructions Manual

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-UD09HE5-1:
Table of Contents

Advertisement

Available languages

Available languages

Menu
6.2
*
*

Cool

1,
2
To set various water & ambient
temperatures for cooling.
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
Default Setting
Setting Options / Display
T for heating ON
Set T for heating
5 °C
ON.
Outdoor temp. for heater ON
Temperature for
0 °C
heater ON
Water temperatures for cooling ON
and T for cooling ON.
Water temp. for cooling ON
Cooling ON
temperatures in
Compensation curve
compensation curve
or direct input.
Water temp. for cooling ON Compensation curve
Input the 4
temperature points
X axis: 20 °C, 30 °C
(2 on horizontal X
Y axis: 15 °C, 10 °C
axis, 2 on vertical Y
axis)
• If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
• "Zone 1" and "Zone 2" will not appear on the display if only 1 zone system.
Water temp. for cooling ON Direct
Set temperature for
10 °C
Cooling ON
T for cooling ON
5 °C
Set T for cooling ON
17