6
.
Compressor inside noise is too big or
6
.
vibration absorption suspending spring is
broken.
Electricity
1
1
.
.
Cabinet body has not been connected to
leakage
of
the ground.
cabinet
2
.
The compressor terminal contacts body
2
.
body,
you
shell and causes short circuit.
will
feel
3
.
When the components of electrical
3
.
tingle
when
system get wet, insulation ability is
touching by
dropped, electricity leaks.
hand
Electricity
1
.
The service time is too long.
1
.
leakage
of
2
.
The environment is too dirty.
2
.
temperature
3
3
.
.
Humidity is too high.
controller
1
.
There is leakage of temperature sensing
1
.
Temperature
medium.
controller out
2
.
Damage of cam of contacting point
2
.
of order
spring, etc.
The probe of
temperature
sensing tube
It has not been mounted to position or
doesn't
changed during transportation.
contact
evaporator
well
Issue 2009-03-09
Rev.
Ref0903S021V0
1
1
.
.
Make the ground connection
as stipulated.
2
.
Change compressor.
2
.
3
.
Check carefully step by step,
3
.
if
insulation
is
damaged,
please
remove wet parts and put
them into drying box to make
them dry.
1
1
.
.
Change
temperature
controller.
2
2
.
.
Use brush to remove dust.
3
.
Make the temperature dry
3
.
and control the environment
humidity.
Change temperature controller.
Mount it again.