Wiring Diagram - Wolf Steel 13 SEER Installation Instructions Manual

Table of Contents

Advertisement

9.0 WIRING DIAGRAM

These units must be wired and installed in accordance with all National and
Local Safety Codes.
PLUG PLA TE
L1
RED
BLACK
L2
BLACK
CC
A2
A1
BLACK
GREEN
BLACK
C
COMP
RC 1
R
S
WHITE OR YELLOW
BLACK
BLACK
RED
RC 3
Fig.12 Outdoor Unit Wiring Diagram for Systems(208/230V 1P 60Hz).(JUST FOR 18K/24K/30K)
PLUG PLA TE
L1
RED
BLACK
L2
BLACK
CC
A1
A2
BLACK
YELLOW
GREEN
BLACK
C
COMP
RC 1
R
S
WHITE OR YELLOW
BLACK
BLACK
RED
RC 3
Fig.13 Outdoor Unit Wiring Diagram for Systems(208/230V 1P 60Hz).(JUST FOR 36K/42K/48K/60K)
CAUTION
GROUND
L1
L2
C
Y
YELLOW
BLACK
ORANG E
FAN
RC 2
GREEN
BROWN
BLACK
GROUND
L1
L2
C
Y
YELLOW
HGS
BLACK
ORANG E
FAN
RC 2
GREEN
BROWN
BLACK
LINE VOL T AGE
F ACT OR Y S T ANDARD
FIELD INST ALLED
F ACT OR Y
OPTIONAL
LO W
VOL T AGE
F ACT OR Y S T ANDARD
FIELD INST ALLED
F ACT OR Y O PTIONAL
USE COPPER CONDUCT ORS ONL Y
CC
COMPRESSOR CONT ACT OR
COMP
COMPRESSOR
RC 1
RUN CAP ACIT OR 1
RC 2
RUN CAP ACIT OR 2
RC 3
RUN CAP ACIT OR 3
W ARNING: CABINET MUST BE PERMANMENTL Y
GOUNDED AND ALL WIRING TO CONFORM TO
I.E.C,N.E.C,C.E.C,C.L.C,AND LOCAL CODES AS APPLICABLE
REPLACEMENT WIRE MUST BE THE SAME GAUGE AND
INSULA TION TYPE AS ORIGINAL WIRE
LINE VOL T AGE
F ACT OR Y S T ANDARD
FIELD INST ALLED
F ACT OR Y
OPTIONAL
LO W
VOL T AGE
F ACT OR Y S T ANDARD
FIELD INST ALLED
F ACT OR Y O PTIONAL
USE COPPER CONDUCT ORS ONL Y
HGS
HO T G AS OR COMPRESSO R T OP SENSO R
CC
COMPRESSOR CONT ACT OR
COMP
COMPRESSOR
RC 1
RUN CAP ACIT OR 1
RC 2
RUN CAP ACIT OR 2
RC 3
RUN CAP ACIT OR 3
W ARNING: CABINET MUST BE PERMANMENTL Y
GOUNDED AND ALL WIRING TO CONFORM TO
I.E.C,N.E.C,C.E.C,C.L.C,AND LOCAL CODES AS APPLICABLE
REPLACEMENT WIRE MUST BE THE SAME GAUGE AND
INSULA TION TYPE AS ORIGINAL WIRE
17