Piping Diagrams; Indoor Unit; Outdoor Unit - LG LSN090HSV4 Svc Manual

Room air conditioner
Hide thumbs Also See for LSN090HSV4:
Table of Contents

Advertisement

2. Piping Diagrams

LS090HSV4 (AS-W09GB1B0), LS120HSV4 (AS-W12GB1B0), LA090HSV4 (AS-W09GBRB0),
LA120HSV4 (AS-W12GBRB0)

Indoor Unit

Th2
Th1
Heat
Exchanger
(Evaporator)
Th3
Th4
Th5
LOC.
Th1
Thermistor for indoor air temperature
Th2
Thermistor for evaporator inlet temperature
Th3
Thermistor for evaporator middle temperature
Th4
Thermistor for evaporator outlet temperature
Th5
Water Level Sensor (Option)
Th6
Thermistor for outdoor air temperature
Th7
Thermistor for condensing temperature
Th8
Thermistor for discharge pipe temperature
※ EEV : Electronic Expansion Valve
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
FIELD PIPIN G
(Ø 1/4" Copper Tubing)
Liquid Side
M
FIELD PIPIN G
(Ø 3/8" Copper Tubing)
Gas Side
Description

Outdoor Unit

2-Way Valve
EEV
3-Way Valve
Accumulator
Compressor
- 5 -
Th6
Heat
M
Exchanger
(Condenser)
Reversing
Th7
Valve
Th8
: Cooling
: Heating
PCB Connector
CN-TH1 (Indoor)
CN-TH2 (Indoor)
CN-TH3 (Indoor)
CN-TH1 (Outdoor)
CN-TH2 (Outdoor)
LGE Internal Use Only