Schlage WRI-IN-12VDC Installation Instructions Manual
Schlage WRI-IN-12VDC Installation Instructions Manual

Schlage WRI-IN-12VDC Installation Instructions Manual

Wireless reader interface - indoor

Advertisement

Quick Links

Wireless Access
INSTALLATION INSTRUCTIONS
WIRELESS READER
INTERFACE - INDOOR
(WRI-IN-12VDC or AUWRI-IN-12VDC)
The most current version of this document is available for download at:
http://www.ir-swa.com
P/N: M053-014-C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WRI-IN-12VDC and is the answer not in the manual?

Questions and answers

Summary of Contents for Schlage WRI-IN-12VDC

  • Page 1 Wireless Access INSTALLATION INSTRUCTIONS WIRELESS READER INTERFACE - INDOOR (WRI-IN-12VDC or AUWRI-IN-12VDC) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-014-C...
  • Page 2 Wireless Access Schlage Ingersoll Rand Security Technologies 245 W. Roosevelt Road, Building 7, Suite 48 West Chicago, IL 60185 main: 800-313-2962 (630-876-5680) technical support: 866-322-1237 fax: 630-293-4257 web: ir-swa.com Copyright © 2003-2006 Ingersoll Rand, all rights reserved. No part of this document can be reproduced, transmitted, or transcribed in any form by electrical, mechanical, optical, manual, or otherwise without the prior written consent of Ingersoll Rand.
  • Page 3: Table Of Contents

    INSTALLATION INSTRUCTIONS Wireless Reader Interface - Indoor (WRI-IN) NOTE: These instructions are for installing the Wireless Reader Interface - Indoor (WRI-IN-12VDC), a component of a Schlage Wireless Access System. AUWRI-IN-12VDC is an Australian version of the indoor wireless reader interface.
  • Page 4: Schlage Wireless Access System Components

    Wireless Access 1. Schlage Wireless Access System Components 1.1 Overview Every access control system that uses Schlage Wireless Access contains two different types of modules (Figure 1-1): • at least one Wireless Panel Interface Module (WPIM), and • at least one Wireless Access Point Module (WAPM) Figure 1-1 –...
  • Page 5: Wireless Reader Interface - Indoor (Wri-In) Components & Sales Models

    • RF Transceiver Figure 1-3 – Inside the WRI-IN Figure 1-2 – Front of the WRI-IN MODEL MOUNTING LOCATION WRI-IN-12VDC surface indoor AUWRI-IN-12VDC surface indoor Table 1-1- WRI-IN Sales Model Table 2. Installing the WRI-IN 2.1 Tools – Hardware Required •...
  • Page 6: Determining The Best Wpim And Wri-In Locations

    Wireless Access 2.2 Determining the Best WPIM and WRI-IN Locations Proper selection of WPIM and WRI-IN module mounting locations insures reliable RF communications. The WPIM manual contains a section for determining the best location for the WPIM. The maximum distance between WPIM and a WRI-IN is 200’ horizontally when installed inside a building on the same floor that uses normal building construction materials.
  • Page 7: Mounting The Wri-In

    Wireless Access 2.3 Mounting the WRI-IN 2.3.1 TRANSCEIVER CONTROL BOX – A 1” hole is provided in the back of the Transceiver Control Box for routing wires in & out. If needed, additional hole(s) can be drilled in the lower left hand corner of the Transceiver Control Box.
  • Page 8: Getting Wires In & Out Of The Wri-In

    Wireless Access 2.3.5 REQUEST TO EXIT DEVICE – If the installation uses a separate request to exit device, mount it using the manufacturer’s installation instructions. Route the request to exit device wires into the Transceiver Control Box. The request to exit device must have normal open dry contacts that close when request to exit is active.
  • Page 9: Wiring The Wri-In To Its Access Control Peripherals

    Wireless Access 2.5 Wiring the WRI-IN to its Access Control Peripherals There are seven WRI-IN PCB connectors that provide connections to Access Control Peripherals that the WRI-IN will monitor and/or control (Figure 2-4): • DC Input Power • Tamper Input •...
  • Page 10 Wireless Access Figure 2-5 – Typical Access Point Configuration Ingersoll Rand Security Technologies 245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-4257 fax P/N: M053-014-C www.ir-swa.com Page 10 of 18...
  • Page 11 Wireless Access 2.5.1 DC Input Power The DC Input Power connection is mandatory. An external, UL approved, DC power supply that can supply 12 VDC (7-14VDC range) must be provided. The DC power supply must be capable of providing 300 mA of current to power the WRI-IN. Add the power requirements of the access control peripherals connected to the WRI-IN to the 300 mA to determine the overall size of the DC power supply.
  • Page 12 Wireless Access REQUEST R_ENTER A dry contact closure across these terminals initiates a request to enter. ENTER REQUEST R_EXIT A dry contact closure across these terminals initiates a request to exit. EXIT DOOR A dry contact closure across these terminals indicates to the POSITION ACP that the access point portal is closed.
  • Page 13 Wireless Access Figure 2-6 – Portal Output Suppression Diagram Ingersoll Rand Security Technologies 245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-4257 fax P/N: M053-014-C www.ir-swa.com Page 13 of 18...
  • Page 14 Wireless Access 2.5.5 Card Reader/Keypad Any input device with a Wiegand or Clock & Data bit stream can be used with the WRI-IN. A transaction must be a single bit stream of between 4 and 255 bits. The WRI-IN provides a Card Reader interface. Wiring of the Card Reader is optional based on the WRI-IN application.
  • Page 15: Wri-In Cable/Wire Specifications

    “PIM Installation Instruction” manual. If the WPIM is installed, then you are ready to link and configure your Schlage Wireless Access System, please refer to the “Configuring & Operating a Schlage Wireless Access System”...
  • Page 16: Contacting Technical Support

    Wireless Access 4. Contacting Technical Support For questions regarding Schlage Wireless Access: www.ir-swa.com main: 800-313-2962 (630-876-5680) technical support: 866-322-1237 fax: 630-293-4257 Ingersoll Rand Security Technologies 245 W. Roosevelt Road, Bldg 7, Suite 48, West Chicago, IL 60185 / (800) 313-2962 / (630) 293-4257 fax P/N: M053-014-C www.ir-swa.com...
  • Page 17: Fcc Compliance, Aca Compliance & Warnings

    The Australian version of AUWRI-IN-12VDC has been authorized by the Australian Communications Authority (ACA). 5.3 UL Compliance • The Wireless Reader Interface - Indoor (WRI-IN-12VDC) is listed under UL294 as an access control system accessory. • Access equipment manufactured and/or sold by Ingersoll Rand Security Technologies, is not rated for, or intended for use in life safety installations.
  • Page 18: Revision History

    Date Changes X001 03/07/02 preliminary in house release for comments X001.1 03/22/02 made adjusts in text for differences in WRI-IN-12VDC & WRI, added appropriate figures X001.2 04/05/02 updated figures X001.3 05/13/02 added UL changes, corrected grammar errors, changed getting wires in & out...