1. Setting of remote control selector at the
remote control side
Remote Control B Setup
• Press RESET button on the indoor unit to turn the air conditioner
ON.
• Point the remote control at the indoor unit.
• Push and hold CHK • button on the Remote Control by the tip of
the pencil. "00" will show on the display.
• Press ☞
during pushing CHK • "B" will be shown on the
MODE
display and "00" will disappear and the air conditioner will turn
OFF.
The Remote Control B is memorized.
NOTE
• Repeat above step to reset Remote Control to be A.
• Remote Control A have not "A" display.
• Default setting of Remote Control from factory is A.
"B" Display
"00" Display
PRESET
FAN
ONE-TOUCH
MODE
COMFORT
QUIET
SLEEP
SWING
FIX
Hi-POWER
ECO
TIMER
CLR
ON
OFF
SLEEP
SET

Test Operation

To switch the TEST RUN (COOL) mode, press RESET button for 10
seconds. (The beeper will make a short beep.)

Auto Restart Setting

This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power
failure.
Information
The product was shipped with Auto Restart function in the off
position. Turn it on as required.
How to set the Auto Restart
• Press and hold the RESET button for about 3 seconds.
After 3 seconds, the electronic beeper makes three short beeps
to tell you the Auto Restart has been selected.
• To cancel the Auto Restart, follow the steps described in the
section Auto Restart Function of the owner's manual.