4 ON-SCREEN/MENU SWITCHES
4-7 Contents of Menu Switches
[ ]: Factory setting
• The lower section in the items and set values columns shows what's on the VCR's display.
Screens
Items
ALARM/
REC T-MODE
SENSOR
MODE
AL SE 2
DURATION
(VCR's display)
AL SE 3
TAPE END
MODE
AL SE 4
BUZZER
TAPE END
BU 22 1
AL/SENSOR
IN
BU 22 2
ERR WARN
BU 22 3
IN/OUT
CAMERA SW
iO
26
Set values
[2H]
Selects the recording mode for alarm or sensor recording.
6H
(Refer to page 28.)
L12H
L18H
L24H
24H
48H
NORMAL
2H
6H
L12H
L18H
L24H
24H
48H
NORn
5 SEC
Selects the recording duration for alarm or sensor recording.
10 SEC
5 — 180 SEC: Alarm or sensor recording is performed for the specified
15 SEC
30 SEC
CONTINUE: Alarm or sensor recording continues to the end of the tape.
60 SEC
MANUAL:
120 SEC
[180 SEC]
CONTINUE
MANUAL
5
. .
.
180
CONT
nANU
[OFF]
Selects whether or not the Stop mode is forcibly engaged when the tape ends
even if there is an alarm or sensor recording.
STOP
OFF: The forced Stop mode is not engaged.
OFF
STOP
STOP: The Forced Stop mode is engaged.
[OFF]
Sets whether or not the buzzer sounds when the tape ends in the Record mode.
ON
OFF: The buzzer does not sound.
ON: The buzzer sounds when the tape ends during recording. Also, the buzzer
OFF
ON
Selects whether or not the buzzer sounds during alarm or sensor
[OFF]
ON
recording.
OFF: The buzzer does not sound.
OFF
ON: The buzzer sounds.
ON
[OFF]
Sets whether or not the buzzer sounds when a warning occurs.
ON
OFF: The buzzer does not sound.
ON: The buzzer sounds. When the warning is released, the buzzer
OFF
ON
[OFF]
Sets the camera switching signal output interval.
1 FIELD
OFF:
2 FIELD
1 FIELD: Set to this position to switch cameras every 1 field. (However
OFF
1
1FRD
2 FIELD: Set to this position to switch cameras every two fields (1
2FRD
Function
time (5 sec. to 180 sec.)
Alarm or sensor recording continues for as long as alarm
signals are input. Set to this position when specifying the
alarm recording time with a switcher.
*To ensure accurate alarm search and alarm scan operation,
be sure to set the recording time to 5 seconds or more.
• When the tape ends, the mode set with the menu switch <AUTO
REW> or <REPEAT REC> on the <VTR MODE> screen is engaged.
sounds when the tape reel counter value set with the menu switch <CNT
TAPE END> on the SRI/EXT MODE screen is reached.
When the mode is changed by pressing the [REW] button, [EJECT]
button or [OPERATE] button, the buzzer sound stops.
sound stops.
No camera switching signal is output.
1 frame when on 2H or 6H.)
frame).