3. Description
1. Optical lens with manual focus adjustment
2. Hanging bracket with 2 knobs on both sides to fasten the unit and a mounting hole to fix a
mounting hook.
3. Mains input with IEC socket and integrated fuse holder, connect the supplied mains cable
here.
4. Cooling fan
5. Lamp compartment, to be opened with 2 screws.
4. Operation and Technical Specification
• Plugging into the mains power, the fixture starts running. The Inferno runs in automatic
mode.
• Focus adjustable and easy lamp access door.
Specification:
• Voltage: AC 120V~60Hz 230V/240V/250V~50Hz/60Hz
• Fuse: 20mm glass 250V T6.3A / 20mm glass 250V T5A
• Bulb: ELC 24V 250W
• Dimension: 353 x 230 x 132 mm
• Weight:: 7 kgs
Downloaded from
www.Manualslib.com
manuals search engine
5. Lamp installation or replacement
• Always switch off the mains supply and never handle the lamp or luminaire when it is hot.
• Do not touch the bulb with bare hands. If this does happen, clean the lamp with denatured
alcohol and wipe with a lint free cloth before installing.
• Pull the socket off the lamp. Do not pull the wires.
6. Beam angle
The Projector is best to be placed 5 meters from wall, and from this distance the light effect
will cover an area of 3.1 m x 3.1 m.