Verifying Connectivity; Verifying Virtual Disks From The Host - HP StorageWorks 4400 Installation Manual

Enterprise virtual array
Hide thumbs Also See for StorageWorks 4400:
Table of Contents

Advertisement

For ESX 3.0 the default value is set to the Max set value of 256. To set DiskMaxLun to a different
value, in Virtual Infrastructure Client, select Configuration> Advance Settings> Disk> Disk.MaxLun,
and then enter the new value.

Verifying connectivity

To verify proper configuration and connectivity to the SAN:
For ESX 2.5.x, enter the # vmkmultipath -q command.
For ESX 3.x, enter the # esxcfg-mpath -l command.
For each LUN, verify that the multipathing policy is set correctly and that each path is marked on. If
any paths are marked dead or are not listed, check the cable connections and perform a rescan on
the appropriate FCA. For example:
For ESX 2.5.x, enter the # cos-rescan.sh vmhba0 command.
For ESX 3.x, enter the # esxcfg-rescan vmhba0 command.
If paths or LUNs remain missing, see the VMware or HP StorageWorks documentation for
troubleshooting information.

Verifying virtual disks from the host

To verify that the host can access the virtual disks, enter the # more /proc/scsi/scsi command.
The output lists all SCSI devices detected by the server. An EVA4400 LUN entry looks similar to the
following:
Host: scsi3 Channel: 00 ID: 00 Lun: 01
Vendor: HP
Type: Direct-Access
Model: HSV300
HP StorageWorks 4400 Enterprise Virtual Array installation guide
Rev:
ANSI SCSI revision: 02
77