Operating / Safety Instructions Consignes de fonctionnement / sécurité Instrucciones de funcionamiento y seguridad IMPORTANT: IMPORTANT IMPORTANTE: Read Before Using Lire avant usage Leer antes de usar model SKT05 SKT05L www.SitePro.us.com Toll Free: (855) 354-9881...
GENERAL SAFETY RULES Working safely with this instrument is possible only when the operating and safety infor- mation are read completely and the instructions contained therein are strictly followed. The use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Page 4
DISPLAY SYMBOLS AND KEY FUNCTIONS Display Icon Description Vertical angle gradient percentage Angle unit (GON) Battery capacity Slope distance Horizontal distance Height difference Distance unit (meter) distance unit(foot)
Page 5
Primary Function Other Function 1. Start to initial setting of instrument 2. Start to index error set- ting of instrument 3.Start to compensator set- ting of instrument Reticle, board illumination, for SKT05L: laser down centering start-up button 1. Start to initial setting of instrument Horizontal angle 2.
INITIAL SETTING The instrument has many functions. In order to be appropriate to different observation, please do initial setting before observation. SETTING ITEMS Unit of angle setting: °(degree) ‘ (cent) “(second) (360 degrees one circle) (400G one circle) (6400mil one circle) Factory setting °...
SETTING METHOD Press key to turn power on and hold it until all the symbols displayed,then loose the key. After three beeps, loose the key. The instrument will be into initial setting mode. Press key to move the cursor to the next figure. Press key to change the figure.
Page 8
6. Minimum unit of angle displayed, Press key and key for page turning. • ‘DSP 1’ mini display 1” • ‘DSP 5’ mini display 5” 7. Vertical compensator setting, Press key and key for page turning. • ‘VTILT ON’ turn on compensator •...
Battery recharging • Battery should be recharged with the special charger. Insert the battery charger into the power source with 220V or 110V, remove the on-board battery from the main body, and connect the plug of the charger to the charging connector on the battery.
POWER ON INSTRUMENT To turn power ON, Press red key and hold it until all the symbols are displayed. The power is on. SIGHT TARGET Turn telescope to bright background,turn eyepiece knob until reticle can been seen clearly. • Use coarse sighting device to sight target. •...
Page 11
HORIzONTAL AND VERTICAL ANGLE MEASUREMENT Set the mode for horizontal right, Press to change horizontal angle from right to left mode. • If display left,turn the alidade at clockwise to add horizontal angle. • If display left,turn the alidade at counterclockwise to add horizontal angle. Choosing left and right measuring style are decided by observers preference.
Page 12
Press , choose right, turn telescope at counterclockwise, then sight target 1 with cross line center. Press ,horizontal angle of Target 1 turn to be “0” position, then sight target 2 with cross line center,display horizontal angle between 1 and 2 (turning left).
Page 13
Vertical angle “0” setting In initial setting, vertical“0”setting is zenith 0°/horizontal 0°. ZEN=0 (zenith 0°) ZEN=90 (zenith 90°) Measurement of zenith distance and vertical angle zenith Distance If vertical angle is 0° for zenith direction, the vertical angle measured in this way is the zenith distance.
Page 14
Vertical Angle Zenith (90° 00’ 00”) Target 1 Vertical Angle: Q = (L+180°-R) /2 Index difference: I = (L+R-180°) /2 or I = (L+R-540°) /2 Horizontal direction (00° 00’ 00”) If vertical angle is 0° in horizontal direction, then, the vertical angle measured in this way is the perpendicular angle.
DISTANCE MEASUREMENT Distance measurement with stadia hair of the telescope The distance from the measuring object to the instrument can be obtained by using the stadia hair (up and down or left and right) of the telescope, with the accuracy of ≤0.4%L(L: the distance of the target).
Page 16
Circular vial Ajustment is unnecessary if the bubble of the circular vial is in the center after inspection and adjustment of the plate vial. If not,it is necessary. If the bubble of the circular vial is not in the center, bring the bubble to the center by us- ing adjusting pin or adjustable wrench to adjust the bubble adjusting screw.
Page 17
Perpendicularity of aiming axis to horizontal axis(2C) Fix the instrument on tripod and level. Sight at the object A in normal position (left or right ways turning are all acceptable,just keep in same way during inspecting,and please not press ) and read the horizontal angle left Loosen vertical and horizontal clamp screws, and reverse the telescope.
Page 18
Vertical index difference and vertical index zeroing Note:After making adjustments make the inspection as following: Leveling the instrument and turn the power on. Then, sight at a reference A with normal position telescope and obtain the vertical angle (L). Reverse the telescope and sight at the object A again and obtain the vertical angle (R). •...
LASER PLUMMET (SKT05L) Press the twice to activate the laser plummet. To turn off the laser plummet, press twice. ERROR MESSAGE Display TILT: If vertical disc compensator out of range, re-level instrument. If no change, send the instrument to an authorized service dealer for repair/maintenance. Note: the instrument can measure data even turn off compensator in initial status.
WARRANTY LIMITED WARRANTY PROGRAM SitePro warrants the Digital Theodolite to the original purchaser for a period of two (2) years from date of purchase against any defects in material or workmanship. This war- ranty does not cover part failure due to normal wear or tool abuse. For more details of warranty coverage and warranty repair information, call (855) 354-9881.