Control Voltage Out
When a microphone channel turns "on," as indicated by a Selected Channel LED on the front
panel, the channel's associated Control Voltage Out goes "high" (+4 VDC). See chart on page
12 for pin connection. This signal can be used to light indicator lamps, switch speaker zones
on and off, select video cameras, etc. The control voltage should not be connected directly to an
inductive load such as a relay coil, as damage to the mixer may result. Several interface circuit
possibilities are shown in Figure 5 below.
Equivalent Output
Circuit for Control
Voltage Out
Relay Driver
IN4001
CV
10K
G
Figure 5. Control interface examples.
CONTROL
40
VOLTAGE
GND
RELAY
COIL
+
2N3904
Driving Logic Gates
CV
G
Driving One LED
Driving One LED
2v
2v
I
I
R+40
R+40
CV
CV
R
R
G
G
Driving Lamps
CV
10
K
2
N
3904
G
+
13