Error Codes

If an error code appears on the digital display, refer to the following chart for the reason, and a possible remedy for the situation.
Error Code
A0
Abnormal operation: flow control valve
A1
Abnormal operation: by-pass valve
A2
Abnormal operation: fan
A3
Abnormal operation: data communication
A4
Overheating of heat exchanger
A5
Overheating
A6
Ignition error
A7
Abnormal operation: gas valve relay
A8
Abnormal operation: gas valve
A9
Exhaust temperature overheating
AA
Abnormal operation: inlet water sensor
AB
Abnormal operation: heat exchanger temperature sensor
AC
Abnormal operation: hot water temperature sensor
AD
Clog of condensate trap or no water in condensate trap
AE
Blockage of flue Pipe
AF
Low Water Cut Off Switch error
If any of these remedies does not resolve the problem, contact technical support at 1-800-761-0053.
Cause
Contact technical support.
Contact technical support.
• Clean the intake air filter.
• Check the fan connector.
• Contact technical support.
Contact technical support.
• Turn off the system for at least 30 minutes, and then restart
• Contact technical support.
• Turn off the system for at least 30 minutes, and then restart
• Contact technical support.
• Ensure that the main gas supply valve is open.
• Contact technical support.
• Turn off the main gas valve.
• Contact technical support.
• Turn off the main gas valve.
• Contact technical support.
Contact technical support.
Contact technical support.
Contact technical support.
Contact technical support.
• Fill the condensate trap.
• Contact technical support.
• Clean the vent terminal.
• Contact technical support.
• Check the cold water supply.
• Contact technical support
Self-diagnosis/Action
it.
it.
11
Troubleshooting