High! water! usage! with! no!
zones!running!
High! water! usage! over! the!
past! hour! with! no! zones!
running!
Interrupted! water! usage! at!
any!time!
Interrupted!water!usage!over!
the! last! hour! with! no! zones!
running!
Wiring!short!(high!current)!to!
your!solenoid!
Broken!wire!to!your!solenoid!
!
!
!
zone's! water! usage! rate! is! that! much! lower!
than!the!previous!time!this!zone!ran.!
Set! a! number! of! litres/gallons! to! generate! an!
alert! when! that! amount! of! water! usage! is!
detected!when!no!zones!are!running.!This!alert!
is! typically! generated! within! 5! minutes! of! the!
event!happening.!
Set! a! number! of! litres/gallons! to! generate! an!
alert! when! that! amount! of! water! usage! was!
detected! over! the! previous! hour! and! no! zones!
are! running.! This! alert! is! typically! generated!
each!hour!and!can!be!useful!for!detecting!slow!
water!leaks.!
Set! a! number! of! litres/gallons! to! generate! an!
alert! when! the! average! water! is! less! than! that!
amount.!
This! is! most! useful! when! you! need! to! monitor!
continually!running!water.!This!alert!is!typically!
generated! within! 15! minutes! of! the! event!
happening.!
Set! a! number! of! litres/gallons! to! generate! an!
alert! when! the! average! water! use! in! the! last!
hour!is!less!than!that!amount.!
This! is! most! useful! if! you! have! zones! that! run!
every!hour.!
This! alert! is! typically! generated! each! hour! and!
can!be!useful!for!detecting!slow!water!leaks.!
Generate! an! alert! for! high! solenoid! current!
when! a! zone! is! running,! which! may! be! caused!
by!faulty!wiring!or!faulty!solenoid!valve
Generate! an! alert! when! there! is! no! solenoid!
current! when! a! zone! is! running,! which! may! be!
caused! by! broken! wiring! or! non! existent!
solenoid!valve
HWC3006!&!HWC3012!User!Guide!
©!Hydrawise!2016!
Flow!Meter!
Flow!Meter!
Flow!Meter!
Flow!Meter!
Controller!
supporting!
solenoid! current!
measurement!
Controller!
supporting!
solenoid! current!
measurement!
!
Page!30
!
V2.05
Need help?
Do you have a question about the HWC-012-US and is the answer not in the manual?